Rockwell-automation 1734-OA4, Series C POINT I/O 120/220V AC Output Mo User Manual Page 1

Browse online or download User Manual for Equipment Rockwell-automation 1734-OA4, Series C POINT I/O 120/220V AC Output Mo. Rockwell Automation 1734-OA4, Series C POINT I/O 120/220V AC Output Module Installation Instructions User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 24
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Installation Instructions
POINT I/O 120/220V AC Output Module
Catalog numbers 1734-OA2, 1734-OA4, Series C
Table of Contents
Topic Page
Important User Information 2
Environment and Enclosure 3
Preventing Electrostatic Discharge 3
North American Hazardous Location Approval 4
European Hazardous Location Approval 5
Before You Begin 6
Install the Mounting Base 8
Install the Module 9
Install the Removable Terminal Block 11
Remove a Mounting Base 12
Wire the Module 13
Communicate with Your Module 15
Interpret Status Indicators 16
Specifications 18
Page view 0
1 2 3 4 5 6 ... 23 24

Summary of Contents

Page 1 - Installation Instructions

Installation InstructionsPOINT I/O 120/220V AC Output ModuleCatalog numbers 1734-OA2, 1734-OA4, Series CTable of ContentsTopic PageImportant User Info

Page 2 - Important User Information

10 POINT I/O 120/220V AC Output Module Publication 1734-IN009E-EN-E - March 20131. Using a bladed screwdriver, rotate the keyswitch on the mounting

Page 3 - Environment and Enclosure

POINT I/O 120/220V AC Output Module 11Publication 1734-IN009E-EN-E - March 2013Install the Removable Terminal BlockA Removable Terminal Block (RTB

Page 4

12 POINT I/O 120/220V AC Output Module Publication 1734-IN009E-EN-E - March 2013Remove a Mounting BaseTo remove a mounting base, you must remove an

Page 5

POINT I/O 120/220V AC Output Module 13Publication 1734-IN009E-EN-E - March 2013Wire the ModuleWARNING: If you connect or disconnect wiring while t

Page 6 - Before You Begin

14 POINT I/O 120/220V AC Output Module Publication 1734-IN009E-EN-E - March 2013Wiring for 1734-OA2Wiring for 1734-OA4Channel Output Terminal Commo

Page 7

POINT I/O 120/220V AC Output Module 15Publication 1734-IN009E-EN-E - March 2013Communicate with Your ModulePOINT I/O modules send (consume) and re

Page 8 - Install the Mounting Base

16 POINT I/O 120/220V AC Output Module Publication 1734-IN009E-EN-E - March 2013Interpret Status IndicatorsRefer to the following diagram and table

Page 9 - Install the Module

POINT I/O 120/220V AC Output Module 17Publication 1734-IN009E-EN-E - March 2013Indicator Status for ModulesStatus Description Recommended ActionMo

Page 10

18 POINT I/O 120/220V AC Output Module Publication 1734-IN009E-EN-E - March 2013SpecificationsPOINT I/O 120/220V AC Output Module – 1734-OA2, 1734-

Page 11

POINT I/O 120/220V AC Output Module 19Publication 1734-IN009E-EN-E - March 2013Thermal dissipation, max 1734-OA2 – 6.8 BTU @ @ 264V AC1734-OA4 – 1

Page 12 - Remove a Mounting Base

2 POINT I/O 120/220V AC Output Module Publication 1734-IN009E-EN-E - March 2013Important User InformationSolid-state equipment has operational char

Page 13 - Wire the Module

20 POINT I/O 120/220V AC Output Module Publication 1734-IN009E-EN-E - March 2013Vibration IEC 60068-2-6 (Test Fc, Operating): 5 g @ 10...500 HzShoc

Page 14 - Wiring for 1734-OA4

POINT I/O 120/220V AC Output Module 21Publication 1734-IN009E-EN-E - March 2013C-Tick Australian Radiocommunications Act, compliant with: AS/NZS C

Page 15 - Communicate with Your Module

22 POINT I/O 120/220V AC Output Module Publication 1734-IN009E-EN-E - March 2013Notes:

Page 16 - Interpret Status Indicators

POINT I/O 120/220V AC Output Module 23Publication 1734-IN009E-EN-E - March 2013Notes:

Page 17 - Indicator Status for Modules

Rockwell Automation SupportRockwell Automation provides technical information on the Web to assist you in using its products. At http://www.rockwellau

Page 18 - Specifications

POINT I/O 120/220V AC Output Module 3Publication 1734-IN009E-EN-E - March 2013Environment and EnclosurePreventing Electrostatic DischargeATTENTION

Page 19 - General Specifications

4 POINT I/O 120/220V AC Output Module Publication 1734-IN009E-EN-E - March 2013North American Hazardous Location ApprovalThe following information

Page 20 - Certifications

POINT I/O 120/220V AC Output Module 5Publication 1734-IN009E-EN-E - March 2013European Hazardous Location ApprovalThe following applies when the p

Page 21

6 POINT I/O 120/220V AC Output Module Publication 1734-IN009E-EN-E - March 2013Before You BeginYou can use these Series C POINT I/O™ 120/220V AC Ou

Page 22

POINT I/O 120/220V AC Output Module 7Publication 1734-IN009E-EN-E - March 2013Description Description1 Module locking mechanism 6 Interlocking sid

Page 23

8 POINT I/O 120/220V AC Output Module Publication 1734-IN009E-EN-E - March 2013Install the Mounting BaseTo install the mounting base on the DIN rai

Page 24 - Documentation Feedback

POINT I/O 120/220V AC Output Module 9Publication 1734-IN009E-EN-E - March 2013Install the ModuleThe module can be installed before or after base i

Comments to this Manuals