1 Publication 2090-IN001A-EN-P — March 2001
Installation Instructions
900 Watt Passive Shunt Module
Ultra Series drives and controllers can require external power
dissipation when large inertial loads are present. To ensure that drive
faults due to excessive bus voltage do not occur, loads requiring
power dissipation that exceed a drive’s internal shunt capability
require the use of external shunt resistor(s).
The passive shunt (Catalog No. 1398-SR9PF or 2090-UCSR-P900) can
be used with the following products:
As a motor decelerates, power is returned from the motor to the drive
module, causing the bus voltage on the drive to increase. Ultra servo
amplifier products have circuitry that senses the voltage on the drive’s
DC bus and dissipates power when needed. When the bus voltage
reaches the shunt turn-on voltage of the drive, the internal shunt
circuitry allows the excessive regenerated power to be dissipated
through an external resistor. After the bus voltage is reduced to the
turn-off voltage level, the shunt transistor turns-off and no additional
power is dissipated by the shunt resistor.
Drive Catalog No.
ULTRA 200 Drives 1398-DDM-075, -075X, -150, and -150X
ULTRA Plus Drives 1398-PDM-075 and 1398-PDM-150B
Ultra3000 Drives 2098-DSD-075, -075-SE, -075-DN, -075X, -075X-DN, -150,
-150-SE, -150-DN, -150X, and -150X-DN
Ultra5000 Drives 2098-IPD-075, -075-DN, -150, and -150-DN
ATTENTION
!
Using the passive shunt with modules not listed can
cause equipment damage or personal injury.
Page view 0
1 2 3 4 5 6 ... 11 12

Summary of Contents

Page 1 - 900 Watt Passive Shunt Module

1 Publication 2090-IN001A-EN-P — March 2001Installation Instructions900 Watt Passive Shunt ModuleUltra Series drives and controllers can require exter

Page 2 - Installing the Shunt

Publication 2090-IN001A-EN-P — March 2001 10 900 Watt Passive Shunt ModuleNotes

Page 3

Publication 2090-IN001A-EN-P — March 2001900 Watt Passive Shunt Module 11

Page 4 - Dissipation

Publication 2090-IN001A-EN-P — March 2001 PN 0013-1092-001-01Supersedes Publication 1398-5.13 May 1999 © 2001 Rockwell International Corporation. Prin

Page 5 - Figure 3

Publication 2090-IN001A-EN-P — March 2001 2 900 Watt Passive Shunt ModuleInstalling the ShuntOrientation and ClearanceThe following enclosure r

Page 6

Publication 2090-IN001A-EN-P — March 2001900 Watt Passive Shunt Module 3If the work environment dictates, mount the shunt module in an enclosur

Page 7 - Insert wires

Publication 2090-IN001A-EN-P — March 2001 4 900 Watt Passive Shunt Module900 Watt Continuous Dissipation Cabinet LayoutFigure 2 details the pro

Page 8 - Product Specifications

Publication 2090-IN001A-EN-P — March 2001900 Watt Passive Shunt Module 51,800 Watt Continuous Dissipation Cabinet LayoutFigure 3 details the pr

Page 9 - Figure 4

Publication 2090-IN001A-EN-P — March 2001 6 900 Watt Passive Shunt ModuleSecuring the Passive Shunt ModuleThe following procedure assumes you h

Page 10

Publication 2090-IN001A-EN-P — March 2001900 Watt Passive Shunt Module 7Connecting to the Shunt Terminal Block1. Locate the external shunt ter

Page 11

Publication 2090-IN001A-EN-P — March 2001 8 900 Watt Passive Shunt ModuleProduct Specifications Specifications for the passive shunt module are

Page 12

Publication 2090-IN001A-EN-P — March 2001900 Watt Passive Shunt Module 9Figure 4 900 Watt Passive Shunt Module DimensionsMeasurements are in mi