Rockwell Automation 22-WIM-N4S Specifications

Browse online or download Specifications for Networking Rockwell Automation 22-WIM-N4S. Rockwell Automation 22-WIM-N4S Specifications User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 30
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
PowerFlex
®
DSI™ COMMUNICATION ADAPTERS
BACnet
®
MS/TP ADAPTER (22-COMM-B)
ControlNet
COAX ADAPTER (22-COMM-C)
DeviceNet
ADAPTER (22-COMM-D)
EtherNet/IP
ADAPTER (22-COMM-E)
LonWorks
®
ADAPTER (22-COMM-L)
PROFIBUS DP
ADAPTER (22-COMM-P)
RS-232 DF1
MODULE(22-SCM-232)
COMPACT I/O
MODULE (1769-SM2)
DSI EXTERNAL COMMUNICATIONS KIT
DSI WIRELESS INTERFACE MODULE
1203-USB CONVERTER (1203-USB)
Communications
22Comm Cover_NL_8_23.qxd:Layout 1 8/30/06 3:50 PM Page 1
Page view 0
1 2 3 4 5 6 ... 29 30

Summary of Contents

Page 1 - PowerFlex

PowerFlex®DSI™ COMMUNICATION ADAPTERSBACnet®MS/TP ADAPTER (22-COMM-B)ControlNet™COAX ADAPTER (22-COMM-C)DeviceNet™ADAPTER (22-COMM-D)EtherNet/IP™ADAPT

Page 2

PARAMETERSNo. Name Description01 Mode Displays the mode selected by the jumper on the adapter (Single or Multi-Drive).02 BOOTP Sets the DeviceNet node

Page 3

EXAMPLE FAULTNOTIFICATIONEMAILMAIN WEB PAGEAUTO-REFRESHPROCESS DISPLAYAUTO-REFRESHPROCESS DISPLAYCONFIGURATION22comm_E_PP_NL_8_23.qxd:Product_app_prof

Page 4

Publication 22COMM-PP001D-EN-P – July 2006 Copyright ©2006 Rockwell Automation, Inc. All Rights Reserved. Printed in USA.Supersedes Publication 22COM

Page 5

PRODUCT PROFILEThe PowerFlex®DSI LonWorks™adapterprovides an internal LonWorks connection forPowerFlex 40 and PowerFlex 400 drives. It canalso be used

Page 6

Publication 22COMM-PP001D-EN-P – July 2006 Copyright ©2006 Rockwell Automation, Inc. All Rights Reserved. Printed in USA.Supersedes Publication 22COM

Page 7

PRODUCT PROFILEThe PowerFlex®22-COMM-P adapter providesa PROFIBUS DP network connection forPowerFlex 40 and 400 AC drives and other DSI-based host dev

Page 8 - EDS FILES

PARAMETERSNo. Name Description01 Mode Displays the mode selected by the J2 jumper (Single or Multi-Drive).02 Reserved03 Reserved04 P-DP Addr Actual Di

Page 9

PRODUCT PROFILEThe PowerFlex®22-SCM-232 provides an RS-232DF1 connection for PowerFlex 4 and 40 ACdrives and other DSI-based host devices. The module

Page 10 - SPECIFICATIONS

PARAMETERSNo. Name Description01 Adapter Cfg Sets the operation of the serial converter (Auto, Master, Slave, RTU Master, and RTU Pass-thru).02 DF1 Ad

Page 11

PRODUCT PROFILEThe 1769-SM2 module provides a direct 1769platform connection for PowerFlex®4, 40, and400 AC drives, other DSI-based host devices, andM

Page 12

22Comm Cover_NL_8_23.qxd:Layout 1 8/25/06 12:23 PM Page 2

Page 13 - PRODUCT PROFILE

PARAMETERSNo. Name Description01 Config Mode Displays the module’s configuration mode.02 DSI Mode Displays the module’s operating mode (single or mult

Page 14 - RESOURCE FILES

EXAMPLE SYSTEMS0.002.5646.0HzCans/SecBus/VoltPORTMODNET ANET BSTSRUN RUN0.002.5646.0HzCans/SecBus/VoltPORTMODNET ANET BSTSRUN RUNRUN RUN1769-SM2_PP_NL

Page 15

Publication 22COMM-PP001D-EN-P – July 2006 Copyright ©2006 Rockwell Automation, Inc. All Rights Reserved. Printed in USA.Supersedes Publication 22COM

Page 16 - GSD FILE

The DSI External Communications Kit (22-XCOMM-DC-BASE) provides a networkconnection for PowerFlex®4, 40, and 400 ACdrives. Each kit can serve up to 5

Page 17

SPECIFICATIONSCommunications Network Protocol Dependent on installed adapterData Rate Dependent on installed adapterDrive Protocol DSIData Rate 19.2 K

Page 18 - PowerFlex 4-Class Drive

The DSI Wireless Interface Module (WIM)provides a wireless communication interfacebetween a Pocket PC, laptop computer ordesktop computer equipped wit

Page 19

PARAMETERSNo. Name Description01 Adapter Cfg Sets the operating mode of the WIM.02 Adapter Type Displays the present operating mode of the WIM.03 Dri

Page 20 - EXAMPLE I/O IMAGE

The 1203-USB Converter provides direct USBconnectivity to PowerFlex®70 (SC or EC), 700(SC or VC), 700H and 700S drives, PowerFlex4, 40, 40P and 400 dr

Page 21 - EXAMPLE SYSTEMS

PARAMETERS (DPI MODE)No. Name Description01 DPI Port Displays the port on the host drive which the converter is connected.02 Reset Module Resets the

Page 22

4-CLASS CONNECTIVITYCommunicationAdapter / Module Protocol(internal)22-COMM-B22-SCM-23222-COMM-C22-COMM-D22-COMM-E22-COMM-L22-COMM-P1769-SM222-WIM-Nx1

Page 23

The PowerFlex®22-COMM-B adapter providesan internal BACnet MS/TP connection toPowerFlex 40 and 400 drives. It can also beinstalled in a DSI External C

Page 24 - DAISY-CHAINING KITS

Publication 22COMM-PP001D-EN-P – July 2006 Copyright ©2006 Rockwell Automation, Inc. All Rights Reserved. Printed in USA.Supersedes Publication 22COM

Page 25

PARAMETERSNo. Name Description01 Reset Module Resets the adapter or sets the adapter parameters to factory default.02 Comm Loss Action Sets the actio

Page 26 - NETWORK EXAMPLE

PRODUCT PROFILEThe PowerFlex®DSI ControlNet adapter providesredundant coaxial ControlNet connections forPowerFlex 40 or PowerFlex 400 drives. The adap

Page 27

EXAMPLE I/O IMAGE - SINGLE MODEControllerControlNetScannerDSIAdapter Word and I/OOutput Image (Write)Input Image (Read)Message Handler0 Logic Comma

Page 28 - PARAMETERS (SCANport MODE)

PRODUCT PROFILEThe PowerFlex®22-COMM-D adapter provides aDeviceNet network connection for PowerFlex 40AC drives and other DSI-based host devices witha

Page 29 - 4-CLASS CONNECTIVITY

PARAMETERSNo. Name Description01 Mode Displays the mode selected by the jumper on the adapter (Single or Multi-Drive).02 DN Addr Cfg Sets the DeviceNe

Page 30

PRODUCT PROFILEThe PowerFlex®22-COMM-E adapter provides anEtherNet/IP network connection for PowerFlex40 AC drives and other DSI-based host deviceswit

Comments to this Manuals

No comments