Rockwell-automation 1788-CN2DN ControlNet-to-DeviceNet Linking Device User Manual

Browse online or download User Manual for Equipment Rockwell-automation 1788-CN2DN ControlNet-to-DeviceNet Linking Device . Rockwell Automation 1788-CN2DN ControlNet-to-DeviceNet Linking Device Installation Instructions User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 52
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Publication 1788-IN052D-EN-P - February 2007
Installation Instructions
ControlNet-to-DeviceNet Linking Device
Catalog Number 1788-CN2DN
Topic Page
Important User Information 2
About the CN2DN Linking Device 7
Parts List 8
Required System Components 9
Install the CN2DN Device 9
Mount the CN2DN Device on a DIN Rail 10
Mount the CN2DN Device on a Panel or Other Fixture 12
Wire a Power Supply to the CN2DN Device 13
Set the Node Addresses and Communication Rate 15
Connect the CN2DN Device to a ControlNet Network 16
Connect the CN2DN Device to a DeviceNet Network 17
Uninstall the CN2DN Linking Device 19
Interpret the LED Indicators 21
Troubleshoot the DeviceNet Network 29
Troubleshoot the ControlNet Network 46
Specifications 47
Additional Resources 51
Page view 0
1 2 3 4 5 6 ... 51 52

Summary of Contents

Page 1 - Installation Instructions

Publication 1788-IN052D-EN-P - February 2007Installation InstructionsControlNet-to-DeviceNet Linking DeviceCatalog Number 1788-CN2DNTopic PageImportan

Page 2 - Important User Information

10 ControlNet-to-DeviceNet Linking Device Publication 1788-IN052D-EN-P - February 2007Mount the CN2DN Device on a DIN RailComplete the following st

Page 3

ControlNet-to-DeviceNet Linking Device 11Publication 1788-IN052D-EN-P - February 20073. Clip each of the end anchors onto the DIN rail next to the

Page 4

12 ControlNet-to-DeviceNet Linking Device Publication 1788-IN052D-EN-P - February 20075. If you are mounting your CN2DN device in a high-vibration

Page 5 - Environment and Enclosure

ControlNet-to-DeviceNet Linking Device 13Publication 1788-IN052D-EN-P - February 2007Wire a Power Supply to the CN2DN DeviceThe CN2DN device requi

Page 6 - ATTENTION

14 ControlNet-to-DeviceNet Linking Device Publication 1788-IN052D-EN-P - February 20073. Loosen the two left-most terminal screws of the power conn

Page 7

ControlNet-to-DeviceNet Linking Device 15Publication 1788-IN052D-EN-P - February 2007Set the Node Addresses and Communication RateComplete the fol

Page 8 - 1788-CN2DN Parts

16 ControlNet-to-DeviceNet Linking Device Publication 1788-IN052D-EN-P - February 2007Connect the CN2DN Device to a ControlNet NetworkComplete the

Page 9 - Install the CN2DN Device

ControlNet-to-DeviceNet Linking Device 17Publication 1788-IN052D-EN-P - February 2007Connect the CN2DN Device to a DeviceNet NetworkComplete the f

Page 10 - Press Forward

18 ControlNet-to-DeviceNet Linking Device Publication 1788-IN052D-EN-P - February 20072. Wrap the end of the cable with 38 mm (1.5 in.) of shrink w

Page 11

ControlNet-to-DeviceNet Linking Device 19Publication 1788-IN052D-EN-P - February 2007The resistor should bridge the blue and white terminal caviti

Page 12 - Mount Tabs (Optional Use)

2 ControlNet-to-DeviceNet Linking Device Publication 1788-IN052D-EN-P - February 2007Important User InformationSolid state equipment has operationa

Page 13 - + - +

20 ControlNet-to-DeviceNet Linking Device Publication 1788-IN052D-EN-P - February 20074. To remove the CN2DN linking device from the DIN rail, pull

Page 14 - IMPORTANT

ControlNet-to-DeviceNet Linking Device 21Publication 1788-IN052D-EN-P - February 2007Interpret the LED IndicatorsUse the LED indicators on the CN2

Page 15 - CN2DN Device Switches

22 ControlNet-to-DeviceNet Linking Device Publication 1788-IN052D-EN-P - February 2007Module StatusUse the following table to interpret your Module

Page 16

ControlNet-to-DeviceNet Linking Device 23Publication 1788-IN052D-EN-P - February 2007Green, flashing The CN2DN device is functioning but not commu

Page 17 - Braided Shield

24 ControlNet-to-DeviceNet Linking Device Publication 1788-IN052D-EN-P - February 2007Linking Activity StatusThe Linking Activity LED indicator dis

Page 18 - (1.5 in.)

ControlNet-to-DeviceNet Linking Device 25Publication 1788-IN052D-EN-P - February 2007ControlNet Network StatusThe CNet A and CNet B LED indicators

Page 19

26 ControlNet-to-DeviceNet Linking Device Publication 1788-IN052D-EN-P - February 2007DeviceNet Network StatusThe DeviceNet network indicators, DNe

Page 20

ControlNet-to-DeviceNet Linking Device 27Publication 1788-IN052D-EN-P - February 2007Green, steady One or more devices connected and communicating

Page 21 - Interpret the LED Indicators

28 ControlNet-to-DeviceNet Linking Device Publication 1788-IN052D-EN-P - February 2007DNet I/O Status IndicatorLED Indicator I/O Device Status Reco

Page 22 - Module Status

ControlNet-to-DeviceNet Linking Device 29Publication 1788-IN052D-EN-P - February 2007Troubleshoot the DeviceNet NetworkIf DeviceNet network commun

Page 23 - Module Status Indicator

ControlNet-to-DeviceNet Linking Device 3Publication 1788-IN052D-EN-P - February 2007North American Hazardous Location ApprovalThe following Inform

Page 24 - Linking Activity Status

30 ControlNet-to-DeviceNet Linking Device Publication 1788-IN052D-EN-P - February 200770 The address of the device is already in use by another dev

Page 25 - ControlNet Network Status

ControlNet-to-DeviceNet Linking Device 31Publication 1788-IN052D-EN-P - February 200775 Either or both of the following:• The device does not have

Page 26 - DeviceNet Network Status

32 ControlNet-to-DeviceNet Linking Device Publication 1788-IN052D-EN-P - February 200778 Device is configured in scan list, but not communicating.

Page 27 - DNet Network Status Indicator

ControlNet-to-DeviceNet Linking Device 33Publication 1788-IN052D-EN-P - February 200780 Scanner is in idle mode. If desired, put network in run mo

Page 28 - DNet I/O Status Indicator

34 ControlNet-to-DeviceNet Linking Device Publication 1788-IN052D-EN-P - February 200783 Device returns error responses when the scanner attempts t

Page 29

ControlNet-to-DeviceNet Linking Device 35Publication 1788-IN052D-EN-P - February 200786 The device is in idle mode, or not producing data, while t

Page 30 - DeviceNet Status Codes

36 ControlNet-to-DeviceNet Linking Device Publication 1788-IN052D-EN-P - February 200791 Bus-off condition likely due to cable or signal errors.• C

Page 31

ControlNet-to-DeviceNet Linking Device 37Publication 1788-IN052D-EN-P - February 2007View and Interpret Controller Status TagsUse the following pr

Page 32

38 ControlNet-to-DeviceNet Linking Device Publication 1788-IN052D-EN-P - February 20073. Determine which tags you need to view using the following

Page 33

ControlNet-to-DeviceNet Linking Device 39Publication 1788-IN052D-EN-P - February 20074. Scroll through the list of tags to locate the specific tag

Page 34

4 ControlNet-to-DeviceNet Linking Device Publication 1788-IN052D-EN-P - February 2007European Hazardous Location ApprovalEuropean Zone 2 Certificat

Page 35

40 ControlNet-to-DeviceNet Linking Device Publication 1788-IN052D-EN-P - February 20071788-CN2DN Tag Title ExampleTag Titled As_You_Name:I:StausReg

Page 36

ControlNet-to-DeviceNet Linking Device 41Publication 1788-IN052D-EN-P - February 20075. If need to troubleshoot Status Register tags, use the foll

Page 37

42 ControlNet-to-DeviceNet Linking Device Publication 1788-IN052D-EN-P - February 20076. If you need to troubleshoot Status Tags (:S), use the foll

Page 38

ControlNet-to-DeviceNet Linking Device 43Publication 1788-IN052D-EN-P - February 2007Indication that a device is idle.Use the following informatio

Page 39 - 1756-DNB Tag Title Example

44 ControlNet-to-DeviceNet Linking Device Publication 1788-IN052D-EN-P - February 2007Address with an error.Use the following information to interp

Page 40 - 788-CN2DN Tag Title Example

ControlNet-to-DeviceNet Linking Device 45Publication 1788-IN052D-EN-P - February 20077. If you need to troubleshoot the CommandRegister tags, use

Page 41 - Status Register Tag Values

46 ControlNet-to-DeviceNet Linking Device Publication 1788-IN052D-EN-P - February 2007Troubleshoot the ControlNet NetworkIf ControlNet network comm

Page 42

ControlNet-to-DeviceNet Linking Device 47Publication 1788-IN052D-EN-P - February 2007SpecificationsCN2DN Linking Device, 1788-CN2DNAttribute Value

Page 43

48 ControlNet-to-DeviceNet Linking Device Publication 1788-IN052D-EN-P - February 2007Environmental SpecificationsAttribute ValueConducted RF Immun

Page 44

ControlNet-to-DeviceNet Linking Device 49Publication 1788-IN052D-EN-P - February 2007Temperature, Operating IEC 60068-2-1 (Test Ad, Operating Cold

Page 45

ControlNet-to-DeviceNet Linking Device 5Publication 1788-IN052D-EN-P - February 2007Environment and EnclosureATTENTIONThis equipment is intended f

Page 46

50 ControlNet-to-DeviceNet Linking Device Publication 1788-IN052D-EN-P - February 2007CertificationsThe following certifications apply when the pro

Page 47 - Specifications

ControlNet-to-DeviceNet Linking Device 51Publication 1788-IN052D-EN-P - February 2007Additional ResourcesUse the following table to determine whic

Page 48 - Environmental Specifications

Publication 1788-IN052D-EN-P - February 2007 PN 953014-33Supersedes Publication 1788-IN052C-EN-P - May 2001 Copyright © 2007 Rockwell Automation, Inc.

Page 49

6 ControlNet-to-DeviceNet Linking Device Publication 1788-IN052D-EN-P - February 2007Prevent Electrostatic DischargeATTENTIONThis equipment is sens

Page 50 - Certifications

ControlNet-to-DeviceNet Linking Device 7Publication 1788-IN052D-EN-P - February 2007About the CN2DN Linking DeviceUse following graphic to identif

Page 51 - Additional Resources

8 ControlNet-to-DeviceNet Linking Device Publication 1788-IN052D-EN-P - February 2007Two ControlNet connection ports are located on the bottom left

Page 52 - Rockwell Automation Support

ControlNet-to-DeviceNet Linking Device 9Publication 1788-IN052D-EN-P - February 2007Required System ComponentsIn order to install your 1788-CN2DN

Comments to this Manuals