Class Attributes
Attribute ID Access Rule Name Data Type Description
0 Get Family Code USINT 0x00 = DPI Peripheral
0x90 = PowerFlex 755
0xA0 = 20-750-xxxx Series Option Module
0xFF = HIM
1 Get Family Text STRING[16] Text identifying the device.
2 Set Language Code USINT 0 = English
1 = French
2 = Spanish
3 = Italian
4 = German
5 = Japanese
6 = Portuguese
7 = Mandarin Chinese
9 = Dutch
10 = Korean
3 Get Product Series USINT 1 = A
2 = B …
4 Get Number of Components USINT Number of components (for example, main control board, I/O
boards) in the device.
5 Set User Definable Text STRING[16] Text identifying the device with a user-supplied name.
6 Get Status Text STRING[12] Text describing the status of the device.
7 Get Configuration Code USINT Identification of variations.
8 Get Configuration Text STRING[16] Text identifying a variation of a family device.
9 Get Brand Code UINT 0x0001 = Allen-Bradley
11 Get NVS Checksum UINT A 16-bit checksum of the Nonvolatile Storage in a device.
12 Get Class Revision UINT 2 = DPI
13 Get Character Set Code USINT 0 = SCANport HIM
1 = ISO 8859-1 (Latin 1)
2 = ISO 8859-2 (Latin 2)
3 = ISO 8859-3 (Latin 3)
4 = ISO 8859-4 (Latin 4)
5 = ISO 8859-5 (Cyrillic)
6 = ISO 8859-6 (Arabic)
7 = ISO 8859-7 (Greek)
8 = ISO 8859-8 (Hebrew)
9 = ISO 8859-9 (Turkish)
10 = ISO 8859-10 (Nordic)
255 = ISO 10646 (Unicode)
15 Get Languages Supported STRUCT of:
USINT
USINT[n]
Number of Languages
Language Codes (see Class Attribute 2)
16 Get Date of Manufacture STRUCT of:
UINT
USINT
USINT
Year
Month
Day
17 Get Product Revision STRUCT of:
USINT
USINT
Major Firmware Release
Minor Firmware Release
18 Get Serial Number UDINT Value between 0x00000000 and 0xFFFFFFFF
19 Set Language Selected USINT 0 = Default (HIM will prompt at start up)
1 = Language was selected (no prompt)
20 Set Customer-Generated Firmware STRING[36] GUID (Globally Unique Identifier) identifying customer firmware
upgraded into the device.
30 Get International Status Text STRINGN Text describing the status of device with support for Unicode.