DeviceNet CommunicationsFor PanelView Plus and PanelPlus CE Terminals2711PUser Manual

Page 2 - Important User Information

Publication 2711P-UM004B-EN-P - March 200710 DeviceNet Overview2711P-RN10C DeviceNet Module for 400 and 600 Terminals2711P-RN10H DeviceNet Modu

Page 3 - Table of Contents

Publication 2711P-UM004B-EN-P - March 2007DeviceNet Overview 11Module IndicatorsThe DeviceNet communication modules have three indicators: Netw

Page 4 - 4 Table of Contents

Publication 2711P-UM004B-EN-P - March 200712 DeviceNet OverviewDeviceNet Module (MOD) Status IndicatorThis bi-color (green/red) LED provides de

Page 5 - Requirements

Publication 2711P-UM004B-EN-P - March 2007DeviceNet Overview 13DeviceNet Network (NET) Status IndicatorThis bi-color (green/red) LED indicates

Page 6 - 6

Publication 2711P-UM004B-EN-P - March 200714 DeviceNet Overview

Page 7 - Additional Resources

15 Publication 2711P-UM004B-EN-P - March 2007Chapter 2Configure the Terminal as a Slave DeviceChapter ObjectivesThe procedures in this chapter will sh

Page 8 - 8

Publication 2711P-UM004B-EN-P - March 200716 Configure the Terminal as a Slave DeviceConfigure CommunicationsAfter creating your Machine Editio

Page 9 - DeviceNet Overview

Publication 2711P-UM004B-EN-P - March 2007Configure the Terminal as a Slave Device 176. In the Add Device Selection dialog, select the communic

Page 10 - 10 DeviceNet Overview

Publication 2711P-UM004B-EN-P - March 200718 Configure the Terminal as a Slave DeviceConfigure the Slave Inputs and OutputsYou are now ready to

Page 11 - Module Indicators

Publication 2711P-UM004B-EN-P - March 2007Configure the Terminal as a Slave Device 192. In the Address Block Properties dialog, set the Start B

Page 12 - 12 DeviceNet Overview

Important User InformationSolid state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines

Page 13 - ATTENTION

Publication 2711P-UM004B-EN-P - March 200720 Configure the Terminal as a Slave DeviceBecause the device node is the same node as the PanelView

Page 14 - 14 DeviceNet Overview

Publication 2711P-UM004B-EN-P - March 2007Configure the Terminal as a Slave Device 21Create an Input Alias To make connections to objects, alia

Page 15 - Chapter Objectives

Publication 2711P-UM004B-EN-P - March 200722 Configure the Terminal as a Slave DeviceThe Array Count lets you quickly configure multiple aliase

Page 16 - Configure Communications

Publication 2711P-UM004B-EN-P - March 2007Configure the Terminal as a Slave Device 23Configure the Slave Output DataFollow the same procedure t

Page 17

Publication 2711P-UM004B-EN-P - March 200724 Configure the Terminal as a Slave Device3. Right-click the new address block 0-3 Bytes and select

Page 18 - IMPORTANT

Publication 2711P-UM004B-EN-P - March 2007Configure the Terminal as a Slave Device 25Create an Output Alias To make connections to objects, ali

Page 19

Publication 2711P-UM004B-EN-P - March 200726 Configure the Terminal as a Slave DeviceThe slave output is now configured with the following info

Page 20

Publication 2711P-UM004B-EN-P - March 2007Configure the Terminal as a Slave Device 273. With the new shortcut selected and while on the Local t

Page 21 - Create an Input Alias

Publication 2711P-UM004B-EN-P - March 200728 Configure the Terminal as a Slave DeviceBrowse for TagsWhile you are creating an RSView Machine Ed

Page 22

Publication 2711P-UM004B-EN-P - March 2007Configure the Terminal as a Slave Device 29The structure of the DeviceNet Output Table looks like thi

Page 23

3 Publication 2711P-UM004B-EN-P - March 2007Table of ContentsPrefaceAbout This Publication . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 24

Publication 2711P-UM004B-EN-P - March 200730 Configure the Terminal as a Slave Device1. Click Copy in Communication Setup.The following dialog

Page 25 - Create an Output Alias

Publication 2711P-UM004B-EN-P - March 2007Configure the Terminal as a Slave Device 31Configure RSNetWorx for DeviceNet SoftwareThis section sho

Page 26 - Create a Shortcut

Publication 2711P-UM004B-EN-P - March 200732 Configure the Terminal as a Slave Device The Browse for Network dialog opens.6. Select the path of

Page 27 - 4. Click Apply

Publication 2711P-UM004B-EN-P - March 2007Configure the Terminal as a Slave Device 33When the network is scanned, the devices display in the ne

Page 28 - Browse for Tags

Publication 2711P-UM004B-EN-P - March 200734 Configure the Terminal as a Slave Device1. Double-click the PanelView Plus/PanelView Plus CE Devic

Page 29

Publication 2711P-UM004B-EN-P - March 2007Configure the Terminal as a Slave Device 353. Click the Upload button to edit the configuration. When

Page 30

Publication 2711P-UM004B-EN-P - March 200736 Configure the Terminal as a Slave Device6. Under Change of State / Cyclic, set these parameters to

Page 31 - DeviceNet Software

Publication 2711P-UM004B-EN-P - March 2007Configure the Terminal as a Slave Device 37The input data you just configured appears in the top wind

Page 32

Publication 2711P-UM004B-EN-P - March 200738 Configure the Terminal as a Slave Device3. Select the Output tab to view the output table. 4. Clic

Page 33 - PV Plus/PV Plus CE

Publication 2711P-UM004B-EN-P - March 2007Configure the Terminal as a Slave Device 39You are prompted to download the I/O configuration to the

Page 34

Publication 2711P-UM004B-EN-P - March 20074 Table of Contents

Page 35

Publication 2711P-UM004B-EN-P - March 200740 Configure the Terminal as a Slave DeviceMap the PanelView Plus I/O to the 1756-DNB ScanlistYou can

Page 36

Publication 2711P-UM004B-EN-P - March 2007Configure the Terminal as a Slave Device 41When the upload is complete, the module tab will open.4. F

Page 37

Publication 2711P-UM004B-EN-P - March 200742 Configure the Terminal as a Slave Device6. Select the PanelView Plus device and click > to add

Page 38

Publication 2711P-UM004B-EN-P - March 2007Configure the Terminal as a Slave Device 438. Select the Output tab to verify that the PanelView Plus

Page 39 - PanelView Plus terminal

Publication 2711P-UM004B-EN-P - March 200744 Configure the Terminal as a Slave DeviceSummaryThe scanlists are now configured for both the 1756-

Page 40

Publication 2711P-UM004B-EN-P - March 2007Configure the Terminal as a Slave Device 45The By Category tab displays a list of module types.4. Exp

Page 41

Publication 2711P-UM004B-EN-P - March 200746 Configure the Terminal as a Slave DeviceAfter selecting the module, you are prompted to select the

Page 42

Publication 2711P-UM004B-EN-P - March 2007Configure the Terminal as a Slave Device 476. In the New Module dialog, enter these parameters:• name

Page 43

Publication 2711P-UM004B-EN-P - March 200748 Configure the Terminal as a Slave Device8. To view the tags, double-click the Controller Tags icon

Page 44 - Use RSLogix 5000 Software

49 Publication 2711P-UM004B-EN-P - March 2007Chapter 3Configure the Terminal as a ScannerChapter ObjectivesThe procedures in this chapter build on the

Page 45

5 Publication 2711P-UM004B-EN-P - March 2007PrefaceAbout This PublicationPanelView Plus and PanelView Plus CE terminals with a DeviceNet communication

Page 46

Publication 2711P-UM004B-EN-P - March 200750 Configure the Terminal as a ScannerFor each block of data, you will enter the node address of the

Page 47

Publication 2711P-UM004B-EN-P - March 2007Configure the Terminal as a Scanner 513. Right-click the new 4-7 address block Bytes and select Add D

Page 48

Publication 2711P-UM004B-EN-P - March 200752 Configure the Terminal as a Scanner1. Right-click the 4-7 Bytes icon and select Add Alias.

Page 49

Publication 2711P-UM004B-EN-P - March 2007Configure the Terminal as a Scanner 532. In the Alias Properties dialog, select these properties and

Page 50

Publication 2711P-UM004B-EN-P - March 200754 Configure the Terminal as a ScannerConfigure the Scanner Output DataYou are now ready to configure

Page 51

Publication 2711P-UM004B-EN-P - March 2007Configure the Terminal as a Scanner 553. Right-click the new address block 4-7 Bytes and select Add D

Page 52

Publication 2711P-UM004B-EN-P - March 200756 Configure the Terminal as a ScannerCreate an Output AliasSimilar to the input alias, you need to c

Page 53

Publication 2711P-UM004B-EN-P - March 2007Configure the Terminal as a Scanner 57The scanner output is now configured with:• Address block of fo

Page 54

Publication 2711P-UM004B-EN-P - March 200758 Configure the Terminal as a ScannerBrowse for TagsThe structure of the DeviceNet Input Table looks

Page 55

Publication 2711P-UM004B-EN-P - March 2007Configure the Terminal as a Scanner 59The structure of the DeviceNet Output Table looks like this whe

Page 56

Publication 2711P-UM004B-EN-P - March 20076 RSNetWorx for DeviceNet Version 6.0 or later V6.0 or laterRSLogix 5000 15.0 or later 15.0 or laterT

Page 57

Publication 2711P-UM004B-EN-P - March 200760 Configure the Terminal as a ScannerConfigure RSNetWorx for DeviceNetIn this section, you will use

Page 58

Publication 2711P-UM004B-EN-P - March 2007Configure the Terminal as a Scanner 61The 1756-DNB properties dialog opens. 2. Select the Module tab

Page 59

Publication 2711P-UM004B-EN-P - March 200762 Configure the Terminal as a Scanner3. Click Slave Mode button.The Slave Mode configuration dialog

Page 60

Publication 2711P-UM004B-EN-P - March 2007Configure the Terminal as a Scanner 63Map the I/O to the 1756-DNB Image TableYou must now map the I/O

Page 61 - ControlLogix rack

Publication 2711P-UM004B-EN-P - March 200764 Configure the Terminal as a Scanner3. Select the Output tab to view the output table.4. Select nod

Page 62

Publication 2711P-UM004B-EN-P - March 2007Configure the Terminal as a Scanner 65Map the 1756-DNB I/O to the PanelView Plus ScanlistYou are now

Page 63

Publication 2711P-UM004B-EN-P - March 200766 Configure the Terminal as a Scanner2. Select the Scanlist tab to view and edit the PanelView Plus

Page 64

Publication 2711P-UM004B-EN-P - March 2007Configure the Terminal as a Scanner 674. Select the Input tab to verify that the 1756-DNB data is map

Page 65

Publication 2711P-UM004B-EN-P - March 200768 Configure the Terminal as a ScannerPlus output table. The Output tab shows the data mapped correct

Page 66

Publication 2711P-UM004B-EN-P - March 2007Configure the Terminal as a Scanner 69Use RSLogix 5000 SoftwareDuring the first part of the example c

Page 67

Publication 2711P-UM004B-EN-P - March 2007 7Additional ResourcesFor more information on RSView Enterprise or RSView Studio programming software

Page 68

Publication 2711P-UM004B-EN-P - March 200770 Configure the Terminal as a Scanner

Page 69

71 Publication 2711P-UM004B-EN-P - March 2007Appendix ARestore Configuration to Local TabIn some cases, it may be necessary to edit an application aft

Page 70

Publication 2711P-UM004B-EN-P - March 200772 Restore Configuration to Local TabTo allow browsing for tags, open the Communication Setup under t

Page 71 - Copy Configuration to Local

Publication 2711P-UM004B-EN-P - March 2007IndexNumerics2711P-RN10C 92711P-RN10H 9Aaliasinput 21, 51output 25Bbrowsing for 58Ccommunications 16, 49scan

Page 72

Publication 2711P-UM004B-EN-P - March 200774 Index

Page 74 - 74 Index

Publication 2711P-UM004B-EN-P - April 2007 76Supersedes Publication 2711P-UM004A-EN-P - March 2006 Copyright © 2007 Rockwell Automation, Inc. All righ

Page 75

Publication 2711P-UM004B-EN-P - March 20078

Page 76 - Rockwell Automation

9 Publication 2711P-UM004B-EN-P - March 2007Chapter 1DeviceNet OverviewChapter ObjectivesThis chapter provides an overview of:• DeviceNet protocol• Co