22 Rockwell Automation Publication IASIMP-QS032A-EN-P - March 2012
Chapter 1 Prepare the Kinetix 350 Drive Hardware
Wire the Back-up Power Connector
You need a user-supplied, external 24V DC power supply to provide back-up power to the drive.
Complete these steps to wire the BP connector.
1. Verify the user-supplied, external power supply is not powered.
2. Remove the BP connector from
the drive.
3. Remove approximately 6 mm (0.25
in.) insulation from two 1.5 mm
2
(16 AWG) copper wires.
4. Connect a wire from a +24V DC
terminal on the external power
supply to the +24V DC terminal
on the BP connector.
5. Connect a wire from a -24C DC terminal on the external power supply to the -24V DC
terminal on the BP connector.
6. Insert the connector plug into the drive in the location shown above.
IMPORTANT
Do not connect power to the external power supply.
+