Installation Instructions
POINT I/O 4 Channel Analog Current Output
Module
Catalog Number 1734-OE4C
Topic Page
Important User Information 2
Environment and Enclosure 3
Prevent Electrostatic Discharge 4
European Hazardous Location Approval 5
North American Hazardous Location Approval 6
About the Module 7
Install the Mounting Base 8
Install the I/O Module 9
Install the Removable Terminal Block (RTB) 11
Remove a Mounting Base 11
Communicate with Your Module 12
Wire the Current Output Analog Module 14
Interpret the Status Indicators 15
Specifications 17
Additional Resources 22
Page view 0
1 2 3 4 5 6 ... 23 24

Summary of Contents

Page 1 - Installation Instructions

Installation InstructionsPOINT I/O 4 Channel Analog Current Output ModuleCatalog Number 1734-OE4CTopic PageImportant User Information 2Environment and

Page 2 - Important User Information

10 POINT I/O 4 Channel Analog Current Output Module Publication 1734-IN034B-EN-P - November 20101734-TOP Base1. Using a bladed screwdriver, rotate

Page 3 - Environment and Enclosure

POINT I/O 4 Channel Analog Current Output Module 11Publication 1734-IN034B-EN-P - November 2010Install the Removable Terminal Block (RTB)A removab

Page 4

12 POINT I/O 4 Channel Analog Current Output Module Publication 1734-IN034B-EN-P - November 2010Install a 1734-TOPS Base1. Position the base vertic

Page 5

POINT I/O 4 Channel Analog Current Output Module 13Publication 1734-IN034B-EN-P - November 2010Default Data Map for the 1734-OE4C Analog Output Mo

Page 6

14 POINT I/O 4 Channel Analog Current Output Module Publication 1734-IN034B-EN-P - November 2010Wire the Current Output Analog Module Channel Curre

Page 7 - About the Module

POINT I/O 4 Channel Analog Current Output Module 15Publication 1734-IN034B-EN-P - November 2010Interpret the Status Indicators Indicator State Des

Page 8 - Install the Mounting Base

16 POINT I/O 4 Channel Analog Current Output Module Publication 1734-IN034B-EN-P - November 2010Network StatusOff Device is not on-line- Device has

Page 9 - Install the I/O Module

POINT I/O 4 Channel Analog Current Output Module 17Publication 1734-IN034B-EN-P - November 2010Specifications Output SpecificationsAttri

Page 10 - 1734-TOP Base

18 POINT I/O 4 Channel Analog Current Output Module Publication 1734-IN034B-EN-P - November 2010General SpecificationsAttribute ValueModule locatio

Page 11 - Remove a Mounting Base

POINT I/O 4 Channel Analog Current Output Module 19Publication 1734-IN034B-EN-P - November 2010Weight, approx. 36.9 g (1.3 oz)North American temp

Page 12 - Communicate with Your Module

2 POINT I/O 4 Channel Analog Current Output Module Publication 1734-IN034B-EN-P - November 2010Important User Information Solid state equipment ha

Page 13 - Message size: 8 bytes

20 POINT I/O 4 Channel Analog Current Output Module Publication 1734-IN034B-EN-P - November 2010ESD immunity IEC 61000-4-2:6 kV contact discharges8

Page 14

POINT I/O 4 Channel Analog Current Output Module 21Publication 1734-IN034B-EN-P - November 2010CertificationsCertification (when product is marked

Page 15

22 POINT I/O 4 Channel Analog Current Output Module Publication 1734-IN034B-EN-P - November 2010Additional ResourcesThese documents contain additio

Page 16

POINT I/O 4 Channel Analog Current Output Module 23Publication 1734-IN034B-EN-P - November 2010Notes:

Page 17 - Specifications

Rockwell Automation SupportRockwell Automation provides technical information on the Web to assist you in using its products. At http://support.rockwe

Page 18 - General Specifications

POINT I/O 4 Channel Analog Current Output Module 3Publication 1734-IN034B-EN-P - November 2010Environment and Enclosure ATTENTIONThis equipment i

Page 19 - Environmental Specifications

4 POINT I/O 4 Channel Analog Current Output Module Publication 1734-IN034B-EN-P - November 2010Prevent Electrostatic Discharge ATTENTIONThis

Page 20

POINT I/O 4 Channel Analog Current Output Module 5Publication 1734-IN034B-EN-P - November 2010European Hazardous Location Approval European Zone 2

Page 21 - Certifications

6 POINT I/O 4 Channel Analog Current Output Module Publication 1734-IN034B-EN-P - November 2010North American Hazardous Location Approval The foll

Page 22 - Additional Resources

POINT I/O 4 Channel Analog Current Output Module 7Publication 1734-IN034B-EN-P - November 2010About the ModuleNote that this series C product can

Page 23

8 POINT I/O 4 Channel Analog Current Output Module Publication 1734-IN034B-EN-P - November 2010Install the Mounting BaseTo install the mounting bas

Page 24 - Installation Assistance

POINT I/O 4 Channel Analog Current Output Module 9Publication 1734-IN034B-EN-P - November 2010Install the I/O ModuleThe module can be installed be

Comments to this Manuals

No comments