Bulletin 2097 Shunt Resistor 5
Rockwell Automation Publication 2097-IN002E-EN-P - March 2013
Wire the Shunt Resistor
The shunt resistor is wired into connector BC, a 7-pin quick-connect terminal block, which is
plugged into the Shunt/DC Bus terminal on the front of the drive. The shunt resistor connects
between the Positive DC Bus (either BC-1 or 2) and BC-4.
BC Connector Wiring Specifications
Route shunt wires per user manual instructions. For general guidelines when laying out your
panel and mounting your shunt resistor, refer to the System Design for Control of Electrical
Noise Reference Manual, publication GMC-RM001
.
Shunt Resistor Terminal and Connector
BC Pin Description Signal Strip Length Torque Value
1 and 2 Positive DC bus/shunt resistor +
7 mm (0.28 in.) 0.5 N•m (4.5 lb•in)4 Shunt resistor SH
6 and 7 Negative DC bus -
TIP
Replacement connector sets (catalog number 2097-CONN1) are available. Set includes
general purpose power input (IPD) header, back-up power (BP) header, shunt resistor and DC
bus (BC) header, motor power (MP) header, and safe torque off (STO) header.
Item Description
1 Front lower panel of drive
2 7-pin quick-connect terminal block
3 Shunt/DC bus connector (BC)
+
+
SH
-
-
SHUNT/
DC BUS
To Shunt
Resistor
3
2
1
Kinetix 300
Drive Shown
Page view 4
1 2 3 4 5 6 7 8

Comments to this Manuals

No comments