6 Bulletin 2097 Shunt Resistor
Rockwell Automation Publication 2097-IN002E-EN-P - March 2013
Shunt Resistor Specifications
Refer to the Kinetix Servo Drives Specifications Technical Data, publication GMC-TD003, for
drive and shunt resistor combinations. Use Motion Analyzer software to evaluate shunt resistor
selection. Motion Analyzer software uses your motion control profile and load requirements to
determine regeneration needs. Download Motion Analyzer software at
http://www.rockwellautomation.com/en/e-tools/configuration.html.
Cat. No. Resistance
Continuous Power
W
Weight, approx.
kg (lb)
2097-R2 20 150 0.29 (0.64)
2097-R3 30 150 0.29 (0.64)
2097-R4 40 80 0.19 (0.42)
2097-R6 75 150 0.29 (0.64)
2097-R7 150 80 0.19 (0.42)