2–32 Configuring your Reader
Publication 2755-6.14
Hand–Held Port
This feature provides you the option of scanning with a hand–held
scanner. Any of the following 4 options for using the hand–held port
are possible:
Hand–held Port Description
Normal Mode
The laser comes on upon triggering or IR detect and
will stay on for a minimum of 2.5 seconds, if no
black/white transitions are detected. If transitions are
continuously detected, it stays on for a maximum of 5
seconds.
One–shot mode
The laser comes on upon triggering or IR detect and
stays on for approximately 1 second, whether
transitions are detected or not.
Pulsing mode
The laser comes on upon triggering or IR detect and
pulses on for a minimum of 3 times, if no transitions
are detected. If transitions are detected, it pulses on
for a maximum of 6 times.
Test mode
In this mode, the laser remains on at all times. This
mode is strictly a test mode, and for laser safety
purposes, should not be used during normal
operation.