2–14 Configuring your Reader
Publication 2755-6.14
Output/Package Detect Type Description
AC output Duration (sec)
The value entered here determines how long the
Output/alarm output remains active.
Delay Time before activating AC
output (sec)
The value entered here determines how long the
reader delays after its normal activation time before
acivating the output. The default value of 0.0 should
be sufficient for almost all applications. Use this
option only if it is impossible to mount the reader at
the Output location.
Enable programmable ‘No Read’
message
When this option is enabled, you will be able to
program your own no read message. The message
can be up to 10 characters long and can include any
of the human readable ASCII set (20h to 7fh). Note
that the message is right–justified when transmitted
from the reader. If this option is being used with
Wand Emulation output, the reader defaults to output
as Code 39 so the message must be within the
normal Code 39 range of characters.
Retain same symbol timers after
package detect cycle ends
Under normal Package Detect support conditions, the
reader resets scan buffers after a complete sensor
cycle. Same symbol timers prevent multiple reads
during the scan cycle. But as soon as the cycle
completes and the next Package Detect is
recognized, all buffers are cleared and the reader
scans any bar codes in the field. When retain same
symbol buffers with Package Detect is enabled, same
symbol timers do not automatically reset after a
completed sensor cycle. Rather, they reset after the
same symbol timer times out. This feature can be
useful under these 3 conditions: packages are spaced
relatively closely, the bar codes on consecutive
packages are the same and the possibility of a
package triggering a Package Detect while the box is
still in the scan field exists.
Save read and match bar code if
power–down
Under normal operations, when read and match mode
is used, a new read and match bar code is stored
immediately after the reader has been powered–up or
after the reader has been programmed through
StrataSet. When save read and match bar code on
power–down is enabled, the read and match bar code
is saved during a power-down, and a new read and
match is only accepted after programming the reader.
Support dual package detect
inputs
When this option is enabled, the reader uses the
current line sensor ALARM input as the second
Package Detect input. The current line sensor input
acts as the start of activation cycle, and the second
Package Detect input acts as the end of activation
cycle.
Table continued on the next page.