PLC-5 Ethernet Interface Module 9
Publication 1785-IN019B-EN-P - January 2007
Unchecked Autonegotiate Checkbox and Corresponding Port Settings
Checked Autonegotiate Checkbox and Corresponding Port Settings
Email Client Functionality
The controller is an email client that sends an email triggered by a message instruction via a
mail relay server. The controller uses standard SMTP protocol to forward the email to the
relay server. The controller does not receive email.
You must enter the SMTP Server’s IP address into the text box as shown in the following
dialog.
Enter the SMTP IP Address
The controller supports login authentication. If you want the controller to authenticate to the
SMTP server, check the SMTP authentication checkbox. If you select authentication, you
must also use a username and password for each email.
Follow these directions to create an email:
1. Create a message instruction similar to the one below.
The destination (to), the reply (from), and the body (text) are stored as strings in
elements of separate ASCII string files.