Ultrasonic Analog Sensors
IMPORTANT: SAVE THESE INSTRUCTIONS FOR FUTURE USE.
Specifications
General 300 mm Models 800 mm Models
Sensing range [mm (in.)] 30…300
(1.18…11.81)
50…800
(1.96…31.49)
Adjustment range [mm (in.)] 50…300
(1.96…11.81)
70…800
(2.75…31.49)
Blind zone [mm (in.)] 0…30 (0…1.18) 0…50 (0…0.96)
Standard target [mm (in.)] 100 x 100 (3.93 x 3.93)
Frequency Approx. 390 kHz Approx. 255 kHz
Response delay Approx. 30 ms Approx. 100 ms
Operating temperature
[C (F)]
-25…70° (-13…158°)
Storage temperature [C (F)] -40…85° (-40…185°)
Electrical
Operating voltage 10…30V DC (analog voltage models are
15…30V DC)
Output current 200 mA
Current consumption <20 mA
Protection type Short-circuit, reverse polarity, overload
Output
Output type Analog: 4…20 mA/0…10V DC
depending on model*
Resolution 0.4 mm at max. sensing range
Repeat accuracy ±0.5% of full-scale value
Sensitivity adjustment Remote teach/optional programming
cable
Environmental
Enclosure type rating IP67
Shock 30 g, 11 ms
Housing material Brass, nickel-plated
Connection Micro-quick disconnect
Certifications cULus listed and CE marked for all
applicable directives
ATTENTION
If a hazardous condition can result from
unintended operation of this device, access to
the sensing area should be guarded.
Models covered:
Indicator LED
Dimensions [mm (in.)]
873M-D18AI300-D4
Analog current
873M-D18RAI300-D4
Right angle, analog current
873M-D18AI800-D4
Analog current
873M-D18RAI800-D4
Right angle, analog current
873M-D18AV300-D4
Analog voltage
873M-D18RAV300-D4
Right angle, analog voltage
873M-D18AV800-D4
Analog voltage
873M-D18RAV800-D4
Right angle, analog voltage
Operating Mode Red LED Yellow LED Green LED
Teach Mode
Target detected
One flash
Continuous
flash
Off
No target detected
Flashes Off
Target marginal (invalid teach)
Standard Mode
Target present
Off
On
On
Target not present Off
Solid-state devices can be susceptible to radio
frequency (RF) interference depending on the
power and the frequency of the transmitting
source. If RF transmitting equipment is to be
used in the vicinity of the solid-state devices,
thorough testing should be performed to
assure that transmitter operation is restricted
to a safe operating distance from the sensor
equipment and its wiring.
IMPORTANT
M12X1M18X1
LED
M12X1
LED
4
(0.16)
24.5 (0.96)
39.2 (1.54)
67.7 (2.66)
10
(0.39)
10
(0.39)
67 (26.6)
39.2 (1.54)
24.5
(0.96)
Straight Model
Right Angle Model
Page view 0
1 2

Summary of Contents

Page 1 - Ultrasonic Analog Sensors

Installation InstructionsUltrasonic Analog SensorsIMPORTANT: SAVE THESE INSTRUCTIONS FOR FUTURE USE.SpecificationsGeneral 300 mm Models 800 mm ModelsS

Page 2 - Setting Measurement Range

10000231110 Ver 03873M-IN001A-EN-PJune 2013Power, Control and Information Solutions HeadquartersAmericas: Rockwell Automation, 1201 South Second Stree

Comments to this Manuals

No comments