Rockwell-automation 1394-SR10A External Shunt Resistor Kit User Manual Page 3

  • Download
  • Add to my manuals
  • Print
  • Page
    / 6
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 2
3. Using two M10 (3/8 in.) bolts, mount the shunt resistor assembly
vertically on a flat rigid metal surface that will not be subjected to
shock, vibration, moisture, oil mist, dust or corrosive vapors.
Note: To extend the leadwire length up to 15 m (49 ft total
overall length), use MTW, 105° C (302° F), Class H
insulated wire (UL styles 3349, 3374, or equivalent).
Wiring Your External Shunt
Resistor
To wire your 1394-SR10A shunt resistor:
1. Verify that all power is removed from the system as described in
Mounting Your External Shunt Resistor above.
2.
Wiring Your External Shunt Resistor (Series A and B)
1. Open the front door of the 1394 system module.
2. Remove and discard the COL/INT jumper wire from the power
terminal block in the lower right corner, as shown in Figure 2.
If your system module is: Do this:
Series A and B Go to Wiring Your External
Shunt Resistor (Series A and B).
Series C Go to Wiring Your External
Shunt Resistor (Series C).
Jumper
Page view 2