Publication 2361-5.01 July 1998
6-2 Starting Up Your Drive
Table 6.D: Voltage Measurements (1250, 1650, 3000A Drives)
Rated Armature and Field Currents Armature and field current ratings are listed in the electrical
specifications in Appendix A.
Test Points Expected Voltage Measured Voltage
AC Voltages
L1 to L2 Rated AC Input
L2 to L3 Rated AC Input
L3 to L1 Rated AC Input
TB8-1 to TB8-2 Rated DC Field Output
TB5-3 to TB5-12 115V AC (±10%)
Main Control Board
TP51 to TP52 +5V DC (±0.15V)
TP55 to TP57 +12V DC (±0.48V)
TP56 to TP57 -12V DC (±0.48V)
TP58 to TP53 +5V DC (±0.15V)
TP54 to TP53 +12V DC (±0.48V)
Power Stage Interface Board
TP1 to TP7 +24V DC (±6V)