Installation InstructionsGuardLogix ControllersCatalog Numbers 1756-L61S, 1756-L62S, 1756-L63S, 1756-LSPTopic PageNorth American Hazardous Location Ap
10 GuardLogix ControllersPublication 1756-IN045E-EN-P - October 2009Check the BAT Status IndicatorFollow these steps for both the 1756-L6xS contro
GuardLogix Controllers 11Publication 1756-IN045E-EN-P - October 2009Update the ControllerFollow these steps for the 1756-L6xS controller. With Con
12 GuardLogix ControllersPublication 1756-IN045E-EN-P - October 20098. To start the update of the controller, click Finish and then click Yes.Afte
GuardLogix Controllers 13Publication 1756-IN045E-EN-P - October 2009To connect a workstation to the serial port, use one of these cables:• 1756-CP
14 GuardLogix ControllersPublication 1756-IN045E-EN-P - October 2009Choose the Operating Mode of the ControllerReplace the BatteryIMPORTANT• Contr
GuardLogix Controllers 15Publication 1756-IN045E-EN-P - October 2009Because the GuardLogix controller is a 1oo2 controller (two processors), we st
16 GuardLogix ControllersPublication 1756-IN045E-EN-P - October 2009General SpecificationsCat. No. 1756-L61S 1756-L62S 1756-L63S 1756-LSPMemory -
GuardLogix Controllers 17Publication 1756-IN045E-EN-P - October 2009Environmental SpecificationsAttribute ValueTemperature, operatingIEC 60068-2-1
18 GuardLogix ControllersPublication 1756-IN045E-EN-P - October 2009CertificationsWhen marked, the components have the following certifications. S
GuardLogix Controllers 19Publication 1756-IN045E-EN-P - October 2009Additional ResourcesResource DescriptionGuardLogix Controllers User Manual, pu
2 GuardLogix ControllersPublication 1756-IN045E-EN-P - October 2009Important User InformationSolid state equipment has operational characteristics
Publication 1756-IN045E-EN-P - October 2009 PN-53510Supersedes Publication 1756-IN045D-EN-P - July 2008 Copyright © 2009 Rockwell Automation, Inc. All
GuardLogix Controllers 3Publication 1756-IN045E-EN-P - October 2009North American Hazardous Location ApprovalThe following information applies whe
4 GuardLogix ControllersPublication 1756-IN045E-EN-P - October 2009Environment and Enclosure InformationGeneral Safety InformationPreventing Elect
GuardLogix Controllers 5Publication 1756-IN045E-EN-P - October 2009Prepare the ChassisBefore you install a controller, follow these preliminary st
6 GuardLogix ControllersPublication 1756-IN045E-EN-P - October 2009Install a CompactFlash Card1. Turn the keyswitch to the PROG position.2. Open t
GuardLogix Controllers 7Publication 1756-IN045E-EN-P - October 2009Remove a CompactFlash Card 1. If the OK status indicator is flashing green, wai
8 GuardLogix ControllersPublication 1756-IN045E-EN-P - October 2009Connect the BatteryThis controller contains a lithium battery, which is intende
GuardLogix Controllers 9Publication 1756-IN045E-EN-P - October 2009Install the Controller into the Chassis1. Insert the key into the 1756-L6xS con