Rockwell-automation 2099-K7KCB-1 Kinetix 7000 DC-DC Converter and Cont User Manual Page 8

  • Download
  • Add to my manuals
  • Print
  • Page
    / 16
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 7
Publication 2099-IN002B-EN-P — October 2008
8 Kinetix 7000 DC-DC Converter and Control Board Kits
Install the DC-DC Converter
Kit
Follow these steps to remove and replace the dc-dc converter cassette.
1. Loosen the upper and lower dc-dc converter screws.
T
urn the screws until the latch disengag
es from the cassette. The upper
screw and latch are shown, the lower screw latches the same way.
2. Remove the dc-dc converter wiring harness.
Un
plug the two connectors and route through slot in cassette
.
3. Pull the dc-dc con
verter cassette straight out and away from the drive.
4. Replace the dc-dc converter cassette.
5. Replace the wiring harness.
Route the two connectors back through the
slot in the cassette and
reseat the two-position and three-position connectors.
6. Tighten the upper and lower dc-dc converter screws.
T
urn the screws until the latch engages with the cassette. The upper
screw and latch are
shown, the lower screw latches the same way. Torque
screws to 0.45 N•m (4.0 in•lb).
7. Replace the dc-dc converter cassette and drive covers.