Rockwell-automation GV3000/SE AC Bookshelf Drive Hardware Ref, Install User Manual Page 22

  • Download
  • Add to my manuals
  • Print
  • Page
    / 96
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 21
2-8
GV3000/SE AC Bookshelf Drive Hardware Reference, Version 6.06
Step 7. Locate jumper J4 on the Regulator board. Refer to figure 2.6.
Step 8. Locate pin 1 on jumper J4. Move the jumper to the desired setting as shown
in figure 2.7.
Step 9. Reattach the cover. For 24 to 43 A drives, reattach the front panel before
reattaching the cover.
Important: Check that the display cable is reconnected to the Regulator board. You
will need to fold and route the cable under the heatsink before replacing
the cover.
Step 10. Reconnect wiring to the faceplate of the drive.
Step 11. Reapply input power.
Step 12. Verify that Terminal Strip Analog Input Offset (P.009), Terminal Strip Analog
Input Gain (P.010), and Terminal Strip Analog Input Configure (P.011) are
correctly set.
Note that the jumper settings must match the software settings; otherwise,
the reference value may differ from what is expected. Refer to the
GV3000/SE Bookshelf Drive Software Start-Up and Reference manual for
more information.
2.6.1.2 Setting the Analog Output Jumper (J17)
Jumper J17 is the analog output jumper. This jumper selects either a 0-10 VDC or
4-20 mA scaled signal output that is programmable to be proportional to either speed
or torque using parameter P.012. Refer to the GV3000/SE Bookshelf Drive Software
Start-Up and Reference manual for more information about this parameter. The
analog output signal is available through the terminal strip.
The jumper only selects a 0-10 VDC source voltage or 4-20 mA sink current to
represent speed or torque. Note that the 4-20 mA current selection requires an
external 12 VDC power supply for operation as shown in table 7.6.
Use the following procedure to set jumper J17:
Figure 2.7 Jumper J4 Settings for Analog Input Speed Reference
Current Input Option
Pins 1-2
0-20 mA
J4
V
In
C
In
Volta
g
e Input Option
Pins 2-3
10 VDC
J4
(Default)
V
In
C
In
!
ATTENTION:DC bus capacitors retain hazardous voltages after input
power has been disconnected. After disconnecting input power, wait five
(5) minutes for the DC bus capacitors to discharge and then check the
voltage with a voltmeter to ensure the DC bus capacitors are discharged
before touching any internal components. Failure to observe this
precaution could result in severe bodily injury or loss of life.
Page view 21
1 2 ... 17 18 19 20 21 22 23 24 25 26 27 ... 95 96

Comments to this Manuals