B-12 Run the 1784-KTx Diagnostics for DOS
1784-6.5.22 - November 1999
If you pressed F1, you see:
If an error occurs, the diagnostics report a failure and continues with the next
test. Errors are recorded in the log file (page B-20).
3. Press F10 to return to the main menu (page B-7).
Diagnostic: Description: If this test fails:
Dual Port Tests the computers ability to read
to and write from dual-port memory.
RAM memory may be corrupted
KT
x
card may have a problem
(run the KT
x
card test)
Reset Test Tests the computers ability to reset
the KT
x
card
After reset, verifies the status of the
KT
x
card
KT
x
card may have a problem
(run the KT
x
card test)
Interrupt Tests the interrupt capability from
the KT
x
card to the computer
There may be a conflict in the
interrupt assignments