EtherNet/IP Objects C-23
Class Code
Products such as drives use this object for faults. Modules use this object
for events.
Instances
The number of instances depends on the maximum number of faults or
events supported in the queue. The maximum number of faults/events
can be read in Instance 0, Attribute 1.
Class Attributes
SCANport Fault Object
Hexadecimal Decimal
0x97 151
Instances (Hex.) (Dec.) Device Example Description
0x0000 – 0x3FFF 0 – 16383 Host 0 Class Attributes (Drive)
0x4000 – 0x43FF 16384 – 17407 Module 1 Most Recent Drive Fault
2 Second Most Recent Drive Fault
…
…
16384 Class Attributes (Module)
16385 Most Recent Module Event
…
…
Attribute
ID
Access
Rule Name Data Type Description
0 Set Fault Command
Write
BYTE 0 = No Operation
1 = Clear Fault/Event
2 = Clear Fault/Event Queue
3 = Reset Device
1 Get Number of
Instances
WORD Maximum number of faults/events that the
device can record in its queue
2 Get Fault Trip
Instance Read
BYTE Fault that tripped the device. For modules,
this value is always 1 when faulted.