Rockwell-automation 1336T ControlNet Frn1.02 Rev 1.5 User Manual Page 89

  • Download
  • Add to my manuals
  • Print
  • Page
    / 217
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 88
4–47Using Unscheduled Messaging
Publication 1336 FORCE–5.18 ––March, 1999
This is a write message that stores in the drive your custom product
name/location text string which identifies the product. The text string
is 16 characters long.
PLC Block Transfer Instruction Data
PLC Message Write instruction length: 11 words
PLC Message Read instruction length: 4 words
Header
Word 1
Header
Word 1
PLC Decimal Value
-32507
Header
Word 2
Header
Word 3
Header
Word 2
Header
Word 3
PLC Decimal Value
261 –– Message OK
-32507 –– Message Error
Message Structure
Message Length
11
0
Data
Word 4
Error Code
0
Product Text
Character 2 Character 1
Data
Word 4
Product Text
Character 4 Character 3
Data
Word 5
Product Text
Character 6 Character 5
Data
Word 6
Product Text
Character 8 Character 7
Data
Word 7
Product Text
Character 10 Character 9
Data
Word 8
Product Text
Character 12 Character 11
Data
Word 9
Product Text
Character 14 Character 13
Data
Word 10
Product Text
Character 16 Character 15
Data
Word 11
0
PLC Request –– PLC Message Write
Drive Response –– PLC Message Read
Message Operation
The User Text String Write allows you to write a custom product
identification string to the drive. This string can be 16 ASCII
characters long and is defined in the 8 words of the PMW. You must
enter the characters in the order shown, with the first and second
character of each word entered in opposite order as shown in the
example.
User Text String
User Text String Write
Page view 88
1 2 ... 84 85 86 87 88 89 90 91 92 93 94 ... 216 217

Comments to this Manuals

No comments