Chapter Objectives Chapter 5 contains descriptions of the various inputs and outputs available
on the 1391B-ES Servo Controller. Additionally, a comprehensive listing
and description of the potentiometer and switch adjustments is provided. In
some cases adjustment methods are provided for use during start-up. This
information is provided to help you understand some of the important
aspects about the controller prior to the actual installation and start-up. For
information on shunt regulator adjustments, refer to Chapter 9.
Inputs/Outputs The following paragraphs provide detailed descriptions of the various
inputs and outputs available for the 1391B-ES. See Figure 5.2 for terminal
block locations.
Terminal Block - TB1
Resolver Signals (TB1, Terminals 1-10)
These terminals are used for connection to the resolver. Refer to Appendix
B for connection details.
Terminal Block - TB2
Velocity Command Input (TB2, Terminals 1, 2)
The controller will accept up to a ±10V DC velocity command signal to
achieve maximum motor speed. The plus (+) and minus (–) reference are at
terminals 2 and 1, respectively. Shield must be terminated at source end
only. The differential impedance of the velocity command input is 40k
ohms (20k ohms for single ended inputs).
Signal Common (TB2, Terminals 3, 6, 12, 17)
Signal input reference point.
Buffered Output (TB2, Terminal 4)
This output is the differentially isolated velocity or torque command
applied at terminals 1 and 2 of TB2. It can be wired to the torque command
input (TB2-15 and 16) for torque block operation.