Page view 57
Transformers and Shunt Regulators
Chapter 9
9-56
Figure 9.1
1391 Transformer Wiring Diagrams
H6 H7 H8 H9 H10H1 H2 H3 H4 H5 H11 H12 H13 H14 H15 P1 P2 G1 G0
Y1
Y2
36V AC
CT 200VA
Y3 Y4
Y5
36V AC
CT 200VA
Y6 Y7
Y8
36V AC
CT 200VA
Y9 Y10
Y11
36V AC
CT 200VA
Y12
Faraday
Shield
230V AC230V AC
230V AC
X0
Thermal switch for transformer protection
(rated 115V AC, 1A, 24V DC/0.25A min.,
185° C ±5° C
H1 H3 H2 H4 P1 P2 G0
Y1
Y2
36V AC
CT 200VA
Y3 Y4
Y5
36V AC
CT 200VA
Y6 Y7
Y8
36V AC
CT 200VA
Y9 Y10
Y11
36V AC
CT 200VA
Y12
Faraday
Shield
230V AC230V AC
230V AC
X0
Thermal switch for transformer protection
(rated 115V AC/1A, 24V DC/0.25A min.,
185° C ±5° C)
H6 H5 H7 H9 H8
G1
G2
X1 X2 X3
Primary
Voltage
240V AC
380V AC
415V AC
480V AC
Connect
H2 to H6
H7 to H11
H12 to H1
H3 to H6
H8 to H11
H13 to H1
H4 to H6
H9 to H11
H14 to H1
H5 to H6
H10 to H11
H15 to H1
Lines On
H1
H6
H11
1391-TxxxET
X1 X2 X3
Primary
Voltage
208V AC
240V AC
480V AC
575V AC
Connect
H2 to H6
H7 to H11
H12 to H1
H3 to H6
H8 to H11
H13 to H1
H4 to H6
H9 to H11
H14 to H1
H5 to H6
H10 to H11
H15 to H1
Lines On
H1
H6
H11
1391-TxxxNT
Primary
Voltage
240V AC
480V AC
Connect
H1 to H3 to H8
H2 to H4 to H6
H5 to H7 to H9
H2 to H3
H5 to H6
H8 to H9
Lines On
H1
H4
H7
H1
H4
H7
1391-TxxxDT