Rockwell-automation 5730 DriveLogix5730 Controller for PowerFlex 700S User Manual Page 75

  • Download
  • Add to my manuals
  • Print
  • Page
    / 217
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 74
Configuring DriveLogix Motion 4-5
8. On the Connections tab of the Modules Properties dialog:
a. Change the value on the Requested Packet Interval (RPI) box to
3.0 ms.
b. Click on the Associated Axis tab and click the New Axis button to
assign a channel to Axis00.
c. In the New Tag dialog, create a new tag structure for Axis00 by
typing Axis00 in the Name field and clicking the OK button.
d. On the Associated Axis tab, click the New Axis button to assign a
channel to Axis01.
Page view 74
1 2 ... 70 71 72 73 74 75 76 77 78 79 80 ... 216 217