54 Rockwell Automation Publication 7000-UM201B-EN-P - June 2013
Chapter 4 Drive Terminal Application
Figure 51 - Binary Trigger Data
Figure 52 - Enum Trigger Data
Post Sample Value
The Post Sample value can be set from 0...99%.
To a d j u s t t h e v a l u e :
1. Select the Post Sample field.
2. Press the Soft Keypad Icon and enter the desired value.
Alternatively, a keyboard can be used to type directly into the field.
3. Press OK to accept.
Rate Value
The Rate of which the data is captured can be set from 0...20,000 mSec. A value
of 0 will capture the data as quickly as possible and is determined by loading of
the drive processor.
To a d j u s t t h e r a t e v a l u e :
1. Select the Post Sample field.
2. Press the Soft Keypad Icon and enter the desired value.
Alternatively, a keyboard can be used to type directly into the field.
3. Press OK to accept.