80 Rockwell Automation Publication 750COM-UM007A-EN-P - January 2013
Appendix B Option Module Parameters
About Parameter Numbers
Each parameter set is independently and consecutively numbered.
How Parameters Are
Organized
The Device Parameters and Host Parameters are separately displayed in a
Numbered List view order.
Device Parameters
Configuration Tool Numbering Scheme
HIM
Connected Components Workbench software
DriveExplorer
DriveExecutive
The Device parameters and Host parameters
begin with parameter 01. For example, Device
Parameter 01 - [Port Number] and Host
Parameter 01 - [DL From Net 01] are
parameter 01 as indicated by this manual.
Acyclic Messaging See Chapter 6, Acyclic Messaging for details.
Parameter
No. Name and Description Details
01 [Port Number]
Displays the drive port into which the option
module is installed. Typically, this will be Port 4, 5,
or 6.
Minimum: 4
Maximum: 6
Type: Read Only
02 [DLs From Net Act]
Displays the number of controller-to-drive
Datalinks that the drive is using based on the I/O
connection opened by the controller.
Minimum: 0
Maximum: 16
Type: Read Only
03 [DLs To Net Act]
Displays the number of drive-to-controller
Datalinks that the controller is using based on the
I/O connection opened by the controller.
Minimum: 0
Maximum: 16
Type: Read Only
04 [Net Addr Src]
Displays the source from which the option module
network address is taken. It is either the values of
configured option module Device parameters or
from a DCP-DHCP server.
Values: 0 = DCP-DHCP
1 = Config
Type: Read Only
05 [Reset Module]
No action if set to ‘0’ (Ready). Resets the option
module if set to ‘1’ (Reset Module). Restores the
option module to its factory default settings if set
to ‘2’ (Set Defaults). This parameter is a command.
It will be reset to ‘0’ (Ready) after the command
has been performed.
When performing a Set Defaults, the drive may
detect a conflict. If this occurs, the drive will not
allow a Set Defaults action. You must resolve the
conflict before attempting a Set Defaults action for
the option module.
Default: 0 = Ready
Values: 0 = Ready
1 = Reset Module
2 = Set Defaults
Type: Read/Write
Reset Required: No
ATTENTION: Risk of injury or equipment damage exists. If the option
module is transmitting I/O that controls the drive, the drive may fault
when you reset the option module. Determine how your drive will
respond before resetting the option module.