Rockwell-automation 2755 StrataSet Programming Software User Manual Page 23

  • Download
  • Add to my manuals
  • Print
  • Page
    / 49
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 22
2–12 Configuring your Reader
Publication 2755-6.14
Output/Package Detect Type Description
Support package detect
When this option is enabled, scanning is disabled until
a Package Detect activation is detected. In the first
mode, if the scan duration (see below) is set for less
than 9 seconds, the reader is active for scanning for
the programmed scan duration. In the second mode,
if scan duration is set for greater than 9 seconds, the
reader is active for scanning as long as the sensor
remains active. After a scan cycle completes, the
sensor must turn off momentarily before the next valid
activation is recognized. In the third mode, dual line
sensor support, this value is automatically set to 9.9
seconds.
Support package detect alarm
input
When this option is enabled, the reader produces a
steady stream of beeps, if the sensor alarm is
activated.
Transmit ‘No Read’ message on
package detect timeout
When this option is enabled, the reader transmits NO
READ’ if a no read condition occurs. If a custom
message is desired, refer to programmable no read
message (see below). This function also supports the
following prefixes and suffixes: TAB prefix, CR, LF,
ETX, STX, programmable prefixes and suffixes, and
TAB suffix.
Scans per package detect
activation (1-5)
This option allows you to determine how many
different bar codes the reader expects to see per
sensor activation. To avoid multiple reads of the same
bar code, make sure the same symbol timeout is set
accordingly and the number of scan buffers is equal to
or greater than this number.
Scanner activation time after
package detection (sec)
Support Package Detect must be enabled first before
a value can be entered here. The value here
determines how long the reader will look for a bar
code before timing out. If the value is less than 9
seconds (minimum of .1 seconds), the reader will be
active for this amount of time. If the value is greater
than 9 seconds, the reader remains active as long as
the Package Detect is active. If dual line sensor is
enabled, this value is forced to 9.9 seconds.
Support AC output
When this option is enabled, the reader will activate
the output according to the selections below.
Table continued on the next page.
Page view 22
1 2 ... 18 19 20 21 22 23 24 25 26 27 28 ... 48 49

Comments to this Manuals

No comments