Rockwell-automation 2755 StrataSet Programming Software User Manual Page 24

  • Download
  • Add to my manuals
  • Print
  • Page
    / 49
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 23
2–13Configuring your Reader
Publication 2755-6.14
Output/Package Detect Type Description
AC output Controlled by Host
(DC2/DC4)
When this option is enabled, the host assumes full
control for activating and deactivating the Output. To
turn the Output on, the host must send a CTRL R
(12H) character. To turn the Output off, the host must
send a CTRL T (14H) character. The support Output
option must be enabled first in order to select this
option.
AC output Normally On
The default mode of the reader is to have the Output
normally off. When this option is enabled, the Output
is normally on.
Enable Read and Match mode
This option is an Output function. Support Output
must be enabled before this option is valid. When this
option is enabled, the reader stores in memory the
next bar code it reads after either powering–up or
after being programmed via StrataSet. The reader
emits a unique beep sequence as an indicator that it’s
taking the bar code as a read and match bar code.
From that point on, the Output operates according to
whether output on good read/match is enabled or
output on bad match is enabled. Normally, if this
option is enabled, a new read and match bar code is
stored after each power-up and after each StrataSet
programming session. If desired, you may enable
save read and match bar code (see below) to
preserve the read and match bar code, if power is
lost.
Activate AC output if good
read/match
This option is an Output function. Support Output
must be enabled before this option is valid. When this
option is enabled, if read and match is enabled (see
above), this feature reads “Output on a good match”.
The Output will turn on every time a scanned bar code
matches the read and match bar code. If read and
match is not enabled, the feature reads “fire Output on
good read”. The Output turns on every time the
reader scans a good read.
Activate AC output if bad match
This option is a read and match function as well as an
Output function. Both options must be enabled before
this option is valid. When this option is enabled, the
Output turns on every time a scanned bar code does
not match the read and match bar code. See Enable
read and match option above for details on setting up
for read and match mode.
Activate AC output if no read
This option is a Package Detect function as well as an
Output function. Both options must be enabled before
this option is valid. When this option is enabled, the
Output will turn on if a no read condition occurs. A no
read condition occurs if the reader reaches a sensor
timeout before a bar code is scanned (see support
Package Detect) It also occurs if the line sensor turns
off before a bar code is read (if scan duration is
greater than 9 seconds).
Table continued on the next page.