Troubleshooting
Series Circuit
Unit Response Time (does not include safety control system response time)
Refer to Technical Specifications (page 1) for
certification information and ratings.
Refer to Technical Specifications (page 1) for
certification information and ratings.
Ye l
Red
Brown
Gray
Pink
Blue
24VDC
Power
Supply
1606
-XL120D
Switch 1
+24
RTN
Switch 2
White
White
Ye l
Red
Brown
Gray
Pink
Blue
Actuator 1
Actuator 2
Switch 3
White
Ye l
Red
Brown
Gray
Pink
Blue
Actuator 3
Switch 4
White
Ye l
Red
Brown
Gray
Pink
Blue
Actuator 4
Switch 5
White
Ye l
Red
Brown
Gray
Pink
Blue
Actuator 5
+24 V
+24 V
+24 V
+24 V
+0 V
+0 V
+0 V
+0 V
+0 V
+0 V
Actuator 2 is in sensing range.
Switch
2 is functioning properly
OSSDs are energize to 24 V
Green LED is ON.
Actuator 3 is in sensing range.
Switch
3 has fault.
See Table Above—Red LED is flashing
Actuator 1 is in sensing range.
Switch
1 is functioning properly
OSSDs are energize to 24 V
Green LED is ON.
Actuator 4 is in sensing range.
Switch
4 is functioning properly.
Series inputs are 0 V .
OSSDs are de-energized to 0V .
Green LED is Flashing to indicate
Series inputs are not 24V.
Actuator 5 is in sensing range.
Switch
5 is functioning properl y.
Series inputs are 0V .
OSSDs are de-energized to 0V.
Green LED is Flashing to indicate
Series inputs are not 24V.
OSSDs are OFF
Recoverable fault
IMPORTANT
IMPORTANT