Troubleshooting F-3
FORCE Amber
(steady)
SFC and/or I/O forces enabled Normal operation No action required
Amber
(blinking)
SFC and/or I/O forces present
but not enabled
Off SFC and/or I/O forces not
present
COMM Off No transmission on channel 0 Normal operation
if channel is not
being used
Green
(blinking)
Transmission on channel 0 Normal operation
if channel is being
used
Indicator Color Description Probable Cause Recommended Action