16 Rockwell Automation Publication 56RF-UM001A-EN-P - October 2011
Chapter 2 RFID Components
Table 3 - LEDs
Transceiver Power Up Sequence
1. Both LEDs OFF.
2. Power status turns green. R/W status turns green for 0.25 seconds.
3. R/W status turns red for 0.25 seconds.
4. R/W status turns off for 3…5 seconds.
5. R/W status turns amber for 0.5 seconds.
6. R/W status turns green.
RFID Tags
RF tags come in many shapes and sizes. In general, the bigger the tag, the longer
the sensing distance from the transceiver. Ta ble 4
summarizes the size of the
memory for each type of tag.
Table 4 - Memory
LED Name LED State Indicates
Module Status
Off There is no power applied to the block.
Green The block is operating in a normal condition.
Red The transceiver has an unrecoverable fault; may need replacing.
Read/Write
Status
Off There is no power applied to the device.
Green The EIP interface block is communicating with the transceiver, but no tag is
present. No errors received.
Amber A tag is present within the antenna field.
Red A communication error has occurred. Examples are: bad read/write, corrupt CRC
Note: If a read/write command is not completed while the tag is within the
field, an error will occur.
Tag Type Total Tag
Memory
User Memory
No. of Bytes No. of Blocks Bytes per Block
SLI 128 B 112 B 28 4
SLI-S 256 B 160 B 40 4
SLI-L 64 B 32 B 8 4
FRAM 2048 B 2 kB 250 8