EtherNet/IP Addressing Chapter 4
The Configuration window appears.
1. Click on the Port Configuration tab.
2. Set the Network Configuration Type to Static (if not already done).
3. Change the IP Address to the new address. In this example, the address will
be changed form 192.168.2.115 to 192.168.3.115.
Click Ye s to confirm the change.
Click OK to close the configuration window.
RSLinx places an X over the RFID adaptor because it can no longer
communicate with it.
Use the same steps to change the IP address of the other devices on the network.
Change the Network adaptor address to 192.168.3.1.