Rockwell-automation 1747-KE,D17476.12 DH-485/RS-232C Interface Module User Manual Page 101

  • Download
  • Add to my manuals
  • Print
  • Page
    / 139
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 100
Publication 1747-UM005B-EN-P - March 2006
Application Examples 8-13
Configuration Data Table
Shown below is the configuration information for N10 in Decimal
radix.
Configuration Data Table
I:1.0
Turn OFF handshake
bit to interface
module.
Rung
2:3
COP
COPY
Source #I:1.0
Dest #N10:10
Length 8
14
] [
O:1.0
Reset 40 second base
timer.
This rung checks that proper data was echoed from the module,
or that 5 seconds passed without interface module response.
Get data from the
interface module.
T4:0
Check the first
word echoed.
( )
O:1.0
14
U
14
] [
I:1.0
14
] [
O:1.0
14
]/[
7
] [
S:4
NEQ
NOT EQUAL
Source A N10:11
0
Source B N10:1
123
Handshake
bit to
module.
Handshake
bit from
module.
Handshake
bit to the
interface
module.
No response
from
interface
module.
Set 5 secs
after data
echo.
Check the last
word echoed.
NEQ
NOT EQUAL
Source A N10:17
0
Source B N10:7
654
(RES)
Turn ON interface
Reset bit.
( )
O:1.0
12
L
Rung
2:4
<END>
Address0123456789
N10:0 6 XXX 456 789 345 678 321 654 0 0
N10:100000000000
N10:200000000000
Page view 100
1 2 ... 96 97 98 99 100 101 102 103 104 105 106 ... 138 139

Comments to this Manuals

No comments