Rockwell-automation 2705 RediSTATION Operator Interface User Manual User Manual

Browse online or download User Manual for Equipment Rockwell-automation 2705 RediSTATION Operator Interface User Manual. Rockwell Automation 2705 RediSTATION Operator Interface User Manual User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 64
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
RediSTATION™
Operator Interface
User Manual
Page view 0
1 2 3 4 5 6 ... 63 64

Summary of Contents

Page 1 - Operator Interface

RediSTATION™ Operator InterfaceUser Manual

Page 2 - Important User Information

Publication 2705-UM001A-EN-P1-4 Overview of RediSTATIONUnpopulated ConfigurationAn unpopulated configuration is available for customer configur

Page 3 - Table of Contents

Publication 2705-UM001A-EN-POverview of RediSTATION 1-5LED IndicatorThe RediSTATION has one bicolor LED (red/green) to show its operating statu

Page 4 - Table of Contents ii

Publication 2705-UM001A-EN-P1-6 Overview of RediSTATIONI/O ConnectorBulletin 800T devices connect to the 12-pin I/O connector on the circuit bo

Page 5 - Contents of Manual

Publication 2705-UM001A-EN-POverview of RediSTATION 1-7Device ConnectionThe RediSTATION receives all power and communications through the Devic

Page 6 - Related Publications

Publication 2705-UM001A-EN-P1-8 Overview of RediSTATIONTypical DeviceNet ConfigurationA DeviceNet network supports multiple RediSTATION devices

Page 7 - Overview of RediSTATION

Publication 2705-UM001A-EN-POverview of RediSTATION 1-9DeviceNet ComponentsDeviceNet cables and components are available from Allen–Bradley as

Page 8 - Description

Publication 2705-UM001A-EN-P1-10 Overview of RediSTATIONCatalog Number ConfigurationThe following catalog number configuration shows how to ord

Page 9 - Custom Configurations

1 Publication 2705-UM001A-EN-PChapter 2Installation and MountingChapter ObjectivesThis chapter describes how to install and mount a standard or custom

Page 10 - Station Features

Publication 2705-UM001A-EN-P2-2 Installation and MountingRemoving the Enclosure CoverTo set the configuration parameters of the RediSTATION and

Page 11 - DIP Switches

Publication 2705-UM001A-EN-PInstallation and Mounting 2-3Setting the DeviceNet Node AddressDIP switches 1 to 6 set the node address (0 to 63) o

Page 12 - I/O Connector

Important User InformationBecause of the variety of uses for the products described in this publication, those responsible for the application and use

Page 13 - Device Connection

Publication 2705-UM001A-EN-P2-4 Installation and MountingSetting the Data RateDIP switches 7 and 8 set the data rate at which the RediSTATION c

Page 14 - Typical DeviceNet

Publication 2705-UM001A-EN-PInstallation and Mounting 2-5Setting the Output Flash RateDIP switch 10 sets the flash rate of the outputs (pilot l

Page 15 - Replacement Parts

Publication 2705-UM001A-EN-P2-6 Installation and MountingRediSTATION DimensionsThe figure below shows the dimensions of the standard RediSTATIO

Page 16 - Catalog Number

Publication 2705-UM001A-EN-PInstallation and Mounting 2-7Mounting the RediSTATIONThe RediSTATION mounts on a flat surface. The back of the uni

Page 17 - Installation and Mounting

Publication 2705-UM001A-EN-P2-8 Installation and MountingSecuring Enclosure CoverAfter setting the DIP switches and mounting the enclosure, sec

Page 18 - Setting the DIP Switches

Publication 2705-UM001A-EN-PInstallation and Mounting 2-9Connecting to the DeviceNet NetworkOn standard units with the sealed connector, it is

Page 19 - 2345678910

Publication 2705-UM001A-EN-P2-10 Installation and Mounting

Page 20 - Setting the Data Rate

1 Publication 2705-UM001A-EN-PChapter 3OperationsChapter ObjectivesThis chapter contains the following sections: Modes of OperationThe RediSTATION has

Page 21 - DeviceNet Termination

Publication 2705-UM001A-EN-P3-2 Operations4. Performs a duplicate node address check to verify that another node is not assigned the same Devic

Page 22 - RediSTATION Dimensions

Publication 2705-UM001A-EN-POperations 3-3Error ModeIn error mode (LED turns red), the RediSTATION monitors the error state for correct operati

Page 23 - Mounting the RediSTATION

i Publication 2705-UM001A-EN-PTable of ContentsPrefaceObjectives. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P-1Intended

Page 24 - Securing Enclosure Cover

Publication 2705-UM001A-EN-P3-4 OperationsDeviceNet OperationsThe Allen-Bradley 1747-SDN and 1771-SDN DeviceNet Scanner Modules are master devi

Page 25 - DeviceNet Network

1 Publication 2705-UM001A-EN-PChapter 4Troubleshooting and MaintenanceChapter ObjectivesThis chapter contains the following sections:Preventive Mainte

Page 26 - Publication 2705-UM001A-EN-P

Publication 2705-UM001A-EN-P 4-2 Troubleshooting and MaintenanceUsing the LED IndicatorThe LED provides status information on RediSTATION oper

Page 27 - Operations

Publication 2705-UM001A-EN-PTroubleshooting and Maintenance 4-3Replacing RediSTATION devicesTo replace a RediSTATION device:1. Remove the (6) e

Page 28 - Run Mode

Publication 2705-UM001A-EN-P 4-4 Troubleshooting and Maintenance7. Mount the circuit board to the back of the 800T devices with the DeviceNet

Page 29 - Resetting the Device

Publication 2705-UM001A-EN-PTroubleshooting and Maintenance 4-5Replacing a Pilot Lamp LightPilot light lamps can be replaced easily without ope

Page 30 - DeviceNet Operations

Publication 2705-UM001A-EN-P 4-6 Troubleshooting and Maintenance

Page 31 - Preventive Maintenance

1 Publication 2705-UM001A-EN-PChapter 5Building a Custom RediSTATIONChapter ObjectivesThis chapter describes how to create a RediSTATION.Custom Build

Page 32 - Using the LED Indicator

Publication 2705-UM001A-EN-P5-2 Building a Custom RediSTATIONOperators and IndicatorsThe RediSTATION supports all Allen-Bradley 800T operators

Page 33 - Replacing RediSTATION

Publication 2705-UM001A-EN-PBuilding a Custom RediSTATION 5-3Assembling the RediSTATIONTo assemble a RediSTATION device:1. Mount the 800T devic

Page 34

Publication 2705-UM001A-EN-PTable of Contents iiOperationsChapter Objectives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1M

Page 35 - Replacing a Pilot Lamp

Publication 2705-UM001A-EN-P5-4 Building a Custom RediSTATIONEvery 2 consecutive pins on the I/O connector connects to an I/O cable connector.

Page 36

Publication 2705-UM001A-EN-PBuilding a Custom RediSTATION 5-53. Mount the circuit board to the back of the 800T devices with the DeviceNet term

Page 37 - Building a Custom RediSTATION

Publication 2705-UM001A-EN-P5-6 Building a Custom RediSTATION5. Plug the DeviceNet terminal block connector into the circuit board.6. Connect g

Page 38 - Operators and Indicators

1 Publication 2705-UM001A-EN-PAppendix ASpecificationsElectricalMechanicalSupply Voltage 11 to 25V DCPower Consumption 7 Watts MaximumInputsMaximum Nu

Page 39 - RediSTATION

Publication 2705-UM001A-EN-PA-2 SpecificationsEnvironmentCommunicationsCertificationsAmbient TemperatureOperating Temperature0 to 55° C (32 to

Page 40

1 Publication 2705-UM001A-EN-PAppendix BDeviceNet InformationThe RediSTATION operates as a slave device on the DeviceNet network. The RediSTATION supp

Page 41

Publication 2705-UM001A-EN-PB-2 DeviceNet InformationDeviceNet Object ClassesThe RediSTATION device supports the following DeviceNet object cla

Page 42 - 20-in lbs

Publication 2705-UM001A-EN-PDeviceNet Information B-3Common ServicesDevice_Status1bit 0 owned 0 = not owned or allocated1 = owned (Group 2 allo

Page 43 - Specifications

Publication 2705-UM001A-EN-PB-4 DeviceNet InformationDeviceNet ObjectClass Code: 03 HexClass AttributesNumber of Instances: 1Instance Attribute

Page 44 - Certifications

Publication 2705-UM001A-EN-PDeviceNet Information B-5Connection ObjectClass Code: 05 HexClass AttributesNumber of Instances: 2Instance 1 Attrib

Page 45 - DeviceNet Information

1 Publication 2705-UM001A-EN-PPrefaceObjectivesThis manual gives an overview of the Bulletin 2705 RediSTATION operator interface and describes how to

Page 46 - Identity Object

Publication 2705-UM001A-EN-PB-6 DeviceNet InformationInstance 2 Attributes (Polled I/O Message)1 xxxxxx = node addressAttribute IDAccess RuleNa

Page 47 - Common Services

Publication 2705-UM001A-EN-PDeviceNet Information B-7Common Services1 For Class, resets all connections to nonexistent. For Instance, resets co

Page 48 - DeviceNet Object

Publication 2705-UM001A-EN-PB-8 DeviceNet InformationCommon ServicesDiscrete Input ObjectsClass Code: 08 HexClass AttributesNumber of Instances

Page 49 - Connection Object

Publication 2705-UM001A-EN-PDeviceNet Information B-9Instance 4 Attributes (Discrete Input Number 4)Common ServicesDiscrete Output Point Object

Page 50

Publication 2705-UM001A-EN-PB-10 DeviceNet InformationInstance 2 Attributes (Discrete Output Number 2)Common ServicesAttribute IDAccess RuleNam

Page 51 - Assembly Objects

1 Publication 2705-UM001A-EN-PAppendix CUser ConfigurationAn unpopulated configuration is available for customer configuration and installation of ope

Page 52 - Discrete Input Objects

Publication 2705-UM001A-EN-P C-2 User ConfigurationSpecifications of DeviceNet Interface BoardElectricalCommunicationsEnvironmentalSupply Volta

Page 53 - Discrete Output Point

Publication 2705-UM001A-EN-PUser Configuration C-3Mounting DimensionsRefer to the following dimensions when mounting the DeviceNet Interface Bo

Page 54

Publication 2705-UM001A-EN-P C-4 User ConfigurationConnecting DevicesThis section shows how to connect devices to the DeviceNet Interface Board

Page 55 - User Configuration

Publication 2705-UM001A-EN-PUser Configuration C-5To simplify wiring, input devices and output devices attach to opposite ends of the I/O conne

Page 56 - DeviceNet Interface Board

Publication 2705-UM001A-EN-P Preface 2Related PublicationsThe following table lists DeviceNet related publications you might want to refer to.P

Page 57 - Mounting Dimensions

Publication 2705-UM001A-EN-P C-6 User Configuration

Page 58 - Connecting Devices

Publication 2705-UM001A-EN-PIndexAassembling a RediSTATION 5-3assembly objectsclass attributes B-7common services B-8number of instances B-7Ccables 1-

Page 59

Publication 2705-UM001A-EN-P2 IndexII/O connector 1-6identity objectclass attributes B-2common services B-3number of instances B-2idle mode 3-2

Page 61

Publication 2705-UM001A-EN-P - June 2000 5 41061-151-01(A)Supersedes Publication 2705-804 - October 1994Supersedes Publication 2705-804.1 - December

Page 62 - 2 Index

1 Publication 2705-UM001A-EN-PChapter 1Overview of RediSTATIONChapter ObjectivesThis chapter provides an overview of the RediSTATION and its features.

Page 63

Publication 2705-UM001A-EN-P1-2 Overview of RediSTATIONDescriptionThe Bulletin 2705 RediStation is a 3-button station that operates on the Devi

Page 64 - Back Cover

Publication 2705-UM001A-EN-POverview of RediSTATION 1-3Standard ConfigurationThe standard RediSTATION unit (Catalog No. 2705-T3DN1A42A) has 2 p

Comments to this Manuals

No comments