Rockwell-automation 2711 Standard PanelView Operator Terminal User Man User Manual Page 176

  • Download
  • Add to my manuals
  • Print
  • Page
    / 292
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 175
176 Publication 2711-UM014G-EN-P - September 2008
Chapter 11 Installing the PV1400 Terminal
7. Install the self-locking nuts hand tight.
8. Alternately tighten the self-locking nuts (use 3/8 in. socket) until
the PV1400 terminal is held firmly against the panel.
The recommended tightening sequence is shown below.
The studs have an integral spacer that prevents the gasket from
being over-compressed. The amount of torque required
increases significantly as the gasket reaches the proper
compression. Tighten nuts to a torque of 1.13 Nm (10 lb-in.).
ATTENTION
Tighten mounting nuts to a torque of 1.13 Nm (10 lb-in.)
to provide a proper seal and prevent potential damage to
the terminal. Allen-Bradley assumes no responsibility for
water or chemical damage to the terminal or other
equipment within the enclosure because of improper
installation. A properly installed terminal has a small
gap between the bezel and enclosure.
1513918
16 15
4
3
7
8
12
11
26141017
1
2
9
10
5
6
4
3
7
8
12
11
Recommended Torque
Sequence Keypad
Terminals
Recommended
Torque Sequence
Touch Terminals
Note the sequence starts at center studs and continues to the corner studs.
Page view 175
1 2 ... 171 172 173 174 175 176 177 178 179 180 181 ... 291 292

Comments to this Manuals

No comments