10 Publication 2711PC-UM001A-EN-P - March 2009
Chapter 1 Overview
Software Support
Each terminal is preloaded with FactoryTalk View Machine Edition
runtime and configuration software that does not require activation.
Applications for the compact terminals are created using FactoryTalk
View Studio software.
Compact Machine Edition applications are restricted to a subset of the
functions allowed on the PanelView Plus terminals.
Maximum of 25 displays
Maximum of 200 alarm messages
Maximum screen resolution of 640 x 480 (VGA)
one connection or shortcut to a single controller using either
RSLinx Enterprise 5.20 or KEPServer Enterprise.
Serial and Ethernet communication only.
If using RSLinx Enterprise, only serial-DF1, serial-DH485 and
Ethernet drivers are supported.
Hardware Configurations
The terminal configurations are fixed and do not support
communication modules. The 1000 touch terminal has a fixed display
module and logic module that cannot be replaced.
Software Requirements Version
FactoryTalk View Studio 5.1 or later
RSLinx Enterprise
(1)
(1)
RSLinx Enterprise software is provided with FactoryTalk View Studio. During software installation, you are
prompted to install RSLinx Enterprise software.
5.20 or later
400 and 600 Configurations
1000 Configuration
1
2
3
4
5
1
2
3
4
5
Item Description
1
USB port
(1)
(1)
The 400 and 600 models have one USB port; the 1000 model have two USB ports.
2 RS-232 serial port
3 10/100BaseT Ethernet port
4 Power input, 24V DC
5 CompactFlash Type 1 card slot