Publication 2711P-QS001A-EN-P - October 2007 71
Review Unsupported Features and Implement Workarounds for Migration Issues Chapter 6
Configure the Set Bit Cursor Point ActiveX Control
Follow these steps to configure the set bit cursor ActiveX control.
1. Double-click the ActiveX
control.
2. Click the Connections tab.
3. Assign a tag or expression
to the Select, Index, and
SBCP connections.
The table defines each
connection.
4. Click OK when done.
Connection Connection type Description
Select Read A zero to non-zero transition activates the control.
If the value of the Index connection matches an assigned SBCP
connection, the Select connection is set to 1.
The control becomes inactive if the value of the connection is zero.
This is a required connection.
Index Read The tag assigned to this connection is typically an integer. Set the initial value
to 1. The ActiveX control will mimic behavior similar to the PanelView ‘e’
terminal, which is to select the first item when the control is used the first
time.
A Ramp button pair is typically assigned to the Index connection with the
limits based on the number of cursor points on the display.
This is a required connection.
SBCP Read/Write The SBCP connections are named SBCP1 through SBCP100. Each represents a
value control of the set bit cursor point object in the PanelView ‘e’ terminal.
The SBCP ActiveX control writes either a 0 or 1 to the SBCP connections. Only
one SBCP connection can be set to 1 at a time.
The value of the Index property determines which SBCP connection to set to
1. If the Index connection is set to 1, then SBCP1 is set to 1 and all others are
set to 0.