108 Rockwell Automation Publication 193-UM011A-EN-P - September 2010
Chapter 10 Using DeviceLogix™
5. Place the cursor on the right of the Bit Input block and press the left mouse
button. Draw a line from the Bit Input block to the In1 of the BOR
function block and double-click the left mouse button to establish a
connection.
6. Repeat steps 4 and 5 to add Input 2 of the EC4 to In2 of the BOR function
block.
7. Using the left mouse button, select the Bit Output block and drag it
to the right of the BOR function block. Double-click on the Bit Input
block to select Output A of the EC4 under the Hardware Boolean Output
set.