Rockwell-automation 2711 Standard PanelView Operator Terminal User Man User Manual Page 261

  • Download
  • Add to my manuals
  • Print
  • Page
    / 292
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 260
Publication 2711-UM014G-EN-P - September 2008 261
Messages, Codes and Self-test Numbers Appendix B
Fault codes appear as a full screen box with Error 635 appears in the
upper left corner. Reset the terminal to clear the condition. If the
problem reoccurs, note the 2-digit code and contact technical support.
20 Autobaud Failure. The autobaud process failed to
detect a valid baud rate within 10 seconds. Occurs if
network traffic is nonexistent or intermittent.
Start the terminal when network traffic exists or use
a fixed baud rate.
23 Nonvolatile Objects have been reset. Nonvolatile
storage of some objects required a full reset on
powerup. Certain nonvolatile values will be reset to
defaults.
Can occur when the daughtercard firmware in the
terminal is upgraded. Clear the message and
continue. If problem reoccurs, contact technical
support.
38 An external client device on the network has
performed a Set Attribute request on the Baud Rate
setting. The baud may be different on next terminal
reset.
Confirm the Active Baud on the Communication
Setup screen of the terminal.
DeviceNet Alert Codes Indicates Recommended Action
DeviceNet Fault Codes Indicates Recommended Action
5 PCCC Message Transaction error during the transfer Should not occur in normal operation. Clear the
message. If problem re-occurs, contact technical
support.
6 Stack overflow fault Should not occur during normal operation. Clear the
message. If problem reoccurs, contact technical
support.
13 Invalid Screen Context Priority Received Should not occur during normal operation. Clear the
message. If problem reoccurs, contact technical
support.
17 Client Object Failed Should not occur during normal operation. Clear the
message. If problem reoccurs, contact technical
support.
18 CAN Chip Failed to initialize Should not occur during normal operation. Clear the
message. If problem reoccurs, contact technical
support.
33 I/O Assembly Remap Error Revalidate the application and download. If problem
re-occurs, contact technical support.
37 The size of a particular channel exceeds the size
limitation set by the daughtercard.
Should not occur during normal operation. Clear the
message. If problem reoccurs, contact technical
support.
39 The application contains more Listen Only channels
that the daughtercard supports.
Reset the terminal. If problem re-occurs, contact
technical support.
20xx Critical Internal DeviceNet firmware fault Should not occur during normal operation. Clear the
message. If problem reoccurs, contact technical
support.
9, 11, 21, 22, 24-32, 34-36 Internal faults associated with
motherboard/daughtercard communication
Should not occur during normal operation. Clear the
message. If problem reoccurs, contact technical
support.
Page view 260
1 2 ... 256 257 258 259 260 261 262 263 264 265 266 ... 291 292