62 Rockwell Automation Publication MP-UM001D-EN-P - September 2013
Chapter 8 Removing and Replacing Components
Cable Carrier Assembly
Removal
Follow these directions to remove the cable carrier assembly.
1. Remove the four pan head screws from junction box side cover.
2. Remove the two button head cap screws (BHCS) from the junction box
cover.
3. Remove the junction box cover assembly.
Figure 14 - Cable Carrier Removal
4. Separate the motor power connector by squeezing the side tabs and pulling
on the housing, but do not pull on the wires.
5. Separate the feedback connector from the circuit board by pushing on the
center tab and pulling up on the connector housing, but do not pull on the
wires.
6. Remove the two SHCS from the cable carrier angle bracket.
7. Lay the cable carrier out flat and mark the location of the end bracket.
8. Loosen, but not remove, the two SHCS securing the end bracket to the
base of the linear stage.
9. Remove the cable carrier.
Cable Carrier Assembly
Installation
Follow the Cable Carrier Assembly Removal procedure in reverse.
TIP
Mark the location of the end bracket before removing the cable carrier, this
makes it easier to align it when reinstalling.
Junction Box Side Cover
Junction Box Cover
Cable Carrier Module
Angle Bracket
End Bracket
Feedback Connector
Motor Power Connector
M3 0.5 X8 LG
Phillips Pan Head Screws (4x)
M4 X 0.7 X 8 LG BHCS (2x)
M4 X 0.7 X 10
LG SHCS (2x)
M3 X 0.5 X 8
LG SHCS (2x)
ATTENTION:
Never pull on wires when disconnecting power and feedback
connectors. Damage to circuit continuity can occur.