Typical Drive System
Diagrams
Typical Kinetix 7000 system installations include three-phase AC configurations,
with and without the line interface module (LIM), and DC common bus
configurations.
Figure 1 - Kinetix 7000 System Configuration with LIM and External Resistive Shunt
MAIN VACMAIN VAC
24V DC
Control Power
External Shunt Module (optional component). See
External Shunt Modules on page 156
for more
information.
2090-XXLF-TCxxxx
AC Line Filter
2094-BL75S
Line Interface Module
(optional component)
460V AC
Three-Phase
Input Power
RSLogix 5000 Software
Input
Logix 5000 Controller
Output
1756-MxxSE SERCOS
Interface Module
2090-SCxxx-x
SERCOS Fiber-Optic Ring
Commissioning
2099-BMxx-S Kinetix 7000 Drive
HPK-Series Motors, RDD-Series Direct Drive Motors, MPM-
B165xx and MPM-B215xx, and MPL-B5xxx, MPL-B6xxx,
MPL-B8xxx, and MPL-B9xxx (shown) Servo Motors
ControlLogix Chassis
Motor Power Cable
Encoder
Feedback
Cable
2090-K6CK-Dxxx
Low Profile Connector Kits for
I/O, Motor Feedback,
and Auxiliary Feedback
Safe-off,
General Purpose I/O,
General Purpose Relay
Connections