Rockwell-automation 2099-BMxx Kinetix 7000 High Power Servo Drive User User Manual Page 167

  • Download
  • Add to my manuals
  • Print
  • Page
    / 190
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 166
Rockwell Automation Publication 2099-UM001D-EN-P - December 2012 167
Interconnect Diagrams Appendix B
Figure 76 - Dual 8720MC-RPS065Bx Regenerative Power Supplies to a Single Kinetix 7000 Drive
IMPORTANT
This configuration requires the power regenerative mode settings as described in the 8720MC Regenerative Power Supply
Installation Manual, publication 8720MC-RM001
, and setting of the power tab in RSLogix 5000 software is set to the
appropriate bus regulator catalog number. Common mode capacitors should be disconnected on DC common bus drives.
DC+
DC-
TB
24V DC
ENABLE
IOD
5
6
GPR2+
GPR
8
7
REGEN COM
REGEN OK
GPIO
STOP* START (RPS On)*
CR1*
L1
L2
L3
TB1
L1 AUX
L2 AUX
L3 AUX
PR1
PR2
PR3
MC1
MC2
TB2
TB1
DC+
DC-
L1
L2
L3
TB1
L1 AUX
L2 AUX
L3 AUX
PR1
PR2
PR3
MC1
MC2
TB2
TB1
DC+
DC-
1
2
E/N
E/N
P
N
MC1*
MC
RST
PWR
0V
24V
COM
IP
RDY
FR
FR
TB3
Additional connections required,
but not shown in this diagram:
1. +24V DC Control Power
2. Motor Feedback, Brake (if used),
and Power
3. Drive I/O and Communications
CR1*
GPR2-
CR1*
MC2*
CB2*
Bonded Cabinet
Ground Bus*
Circuit
Breaker (CB2)*
Input
Fusing*
See Note 2
Three-phase
Contactor (MC2)
Harmonic
Filter*
Varistor*
* Indicates User Supplied Component
*120V/240V AC
or
24V DC
MC2
Three-phase
Contactor (MC1)
Harmonic
Filter*
Varistor*
Single-phase
Contactor
See Note 4
Fault Relay
Contact
DC Bus
Connections
Kinetix 7000 Drive
2099-BMxx-S
Axis n
Control
Stop String
See Notes 6 and 8
Digital I/O
and Power
Connections
DC Line
Fuses*
DC Line
Fuses*
120V AC
or
24V DC*
RPS Stop-Start String
DC Bus
Connections
*Line Reactor
(8720MC for
RPS unit)
*DC Line Fuses
(see table in
Appendix A)
*Line Reactor
(8720MC for
RPS unit)
*Three-phase Input
(+10/-15%)
380V AC RMS, 50 Hz
or 460V AC RMS, 60 Hz
See Note 1
Three-phase AC
Line Filter for
Main Power*
See Note 3
Bonded Cabinet
Ground Bus*
Circuit
Breaker (CB1)*
Input
Fusing*
See Note 2
Three-phase
AC Line Filter
for Main Power*
Single-phase
AC Line Filter*
Single-phase
Contactor*
See Note 4
MC1
Slave
Regenerative
Power Supply
8720MC-RPS065BS
Master
Regenerative
Power Supply
8720MC-RPS065BM
PIFS CN2
PIFS CN3
See Note 10
CB2*
Motion
Control I/O*
See Note 11
Page view 166
1 2 ... 162 163 164 165 166 167 168 169 170 171 172 ... 189 190

Comments to this Manuals