6–21Parameters
Publication 1336 FORCE–5.18 ––March, 1999
353
CntlNet Output 2
[CntlNet Out 2]
CntlNet Out 2 contains the third word or data group
to the PLC controller input image table. The data is
transferred to the PLC controller every rack scan.
The ControlNet Adapter Board can provide this
value directly. Other drive functions can provide this
value through a configuration link.
Parameter Number 353
Parameter Type Read/Write, Sink
Display Units / Drive Units None
Factory Default None
Minimum Value –32767
Maximum Value +32767
File – Group Communications I/O – Channel A
354
CntlNet Output 3
[CntlNet Out 3]
CntlNet Out 3 contains the fourth word or data group
to the PLC controller input image table. The data is
transferred to the PLC controller every rack scan.
The ControlNet Adapter Board can provide this
value directly. Other drive functions can provide this
value through a configuration link.
Parameter Number 354
Parameter Type Read/Write, Sink
Display Units / Drive Units None
Factory Default None
Minimum Value –32767
Maximum Value +32767
File – Group Communications I/O – Channel A
355
CntlNet Output 4
[CntlNet Out 4]
CntlNet Out 4 contains the fifth word or data group
to the PLC controller input image table. The data is
transferred to the PLC controller every rack scan.
The ControlNet Adapter Board can provide this
value directly. Other drive functions can provide this
value through a configuration link.
Parameter Number 355
Parameter Type Read/Write, Sink
Display Units / Drive Units None
Factory Default None
Minimum Value –32767
Maximum Value +32767
File – Group Communications I/O – Channel A