Page view 167
6–26 Parameters
Publication 1336 FORCE–5.18 ––March, 1999
387
Analog Output 1
[Analog Out 1]
Analog Out 1 converts a ±32767 value to a ±10V
signal. The digital value is linked to a 1336 FORCE
source parameter which provides a value that is
scaled and offset. The results are converted to a
voltage signal, where ±2048 results in a ±10V
output.
Parameter Number 387
Parameter Type Read/Write, Sink
Display Units / Drive Units ±32767
Factory Default 0
Minimum Value –32767
Maximum Value +32767
File – Group Communication I/O – Analog Output
388
Analog Output 2
[Analog Out 2]
Analog Out 2 converts a ±32767 value to a ±10V
signal. The digital value is linked to a 1336 FORCE
source parameter which provides a value that is
scaled and offset. The results are converted to a
voltage signal, where ±2048 results in a ±10V
output.
Parameter Number 388
Parameter Type Read/Write, Sink
Display Units / Drive Units ±32767
Factory Default 0
Minimum Value –32767
Maximum Value +32767
File – Group Communication I/O – Analog Output
389
Analog Output 3
[Analog Out 3]
Analog Out 3 converts a ±32767 value to a ±10V
signal. The digital value is linked to a 1336 FORCE
source parameter which provides a value that is
scaled and offset. The results are converted to a
voltage signal, where ±2048 results in a ±10V
output.
Parameter Number 389
Parameter Type Read/Write, Sink
Display Units / Drive Units ±32767
Factory Default 0
Minimum Value –32767
Maximum Value +32767
File – Group Communication I/O – Analog Output
390
Analog Output 4
[Analog Out 4]
Analog Out 4 converts a ±32767 value to a ±10V
signal. The digital value is linked to a 1336 FORCE
source parameter which provides a value that is
scaled and offset. The results are converted to a
voltage signal, where ±2048 results in a ±10V
output.
Parameter Number 390
Parameter Type Read/Write, Sink
Display Units / Drive Units ±32767
Factory Default 0
Minimum Value –32767
Maximum Value +32767
File – Group Communication I/O – Analog Output
391
SCANport Analog Select
[SP Analog Sel]
SP Analog Sel indicates which port (1 through 5) is
to receive the SCANport analog input value that
appears in parameter 338, SP Analog In.
Parameter Number 391
Parameter Type Read/Write, Sink
Display Units / Drive Units None
Factory Default 1
Minimum Value 1
Maximum Value 5
File – Group Communications I/O – Analog Output
Enums 1 = Port 1 2 = Port 2 3 = Port 3
4 = Port 4 5 = Port 5