Page view 165
6–24 Parameters
Publication 1336 FORCE–5.18 ––March, 1999
371
Start Owner
[Start Owner]
Start Owner displays which ports are presently
issuing a valid Start command.
Parameter Number 371
Parameter Type Read Only, Source
Display Units / Drive Units Bits
Factory Default 0
Minimum Value 0
Maximum Value 0FE Hex
File – Group Communications I/O – SCANport Owners
Enums Bit 1 = Port 1 Bit 2 = Port 2 Bit 3 = Port 3 Bit 4 = Port 4
Bit 5 = Port 5 Bit 6 = Channel A Bit 7 = Channel B
372
Jog1 Owner
[Jog1 Owner]
Jog1 Owner displays which ports are presently
issuing a valid Jog1 command.
Parameter Number 372
Parameter Type Read Only, Source
Display Units / Drive Units Bits
Factory Default 0
Minimum Value 0
Maximum Value 0FE Hex
File – Group Communications I/O – SCANport Owners
Enums Bit 1 = Port 1 Bit 2 = Port 2 Bit 3 = Port 3 Bit 4 = Port 4
Bit 5 = Port 5 Bit 6 = Channel A Bit 7 = Channel B
373
Jog2 Owner
[Jog2 Owner]
Jog2 Owner displays which ports are presently
issuing a valid Jog2 command.
Parameter Number 373
Parameter Type Read Only, Source
Display Units / Drive Units Bits
Factory Default 0
Minimum Value 0
Maximum Value 0FE Hex
File – Group Communications I/O – SCANport Owners
Enums Bit 1 = Port 1 Bit 2 = Port 2 Bit 3 = Port 3 Bit 4 = Port 4
Bit 5 = Port 5 Bit 6 = Channel A Bit 7 = Channel B
374
Set Reference Owner
[Set Ref Owner]
Set Ref Owner displays which port currently has
exclusive control in selecting the command
frequency source.
Parameter Number 374
Parameter Type Read Only, Source
Display Units / Drive Units Bits
Factory Default 0
Minimum Value 0
Maximum Value 0FE Hex
File – Group Communications I/O – SCANport Owners
Enums Bit 1 = Port 1 Bit 2 = Port 2 Bit 3 = Port 3 Bit 4 = Port 4
Bit 5 = Port 5 Bit 6 = Channel A Bit 7 = Channel B
375
Local Owner
[Local Owner]
Local Owner displays which port has requested
exclusive control of all drive logic functions. If a port
is in local lockout, all other functions (except stop)
on all other ports are locked out and are
non–functional.
Parameter Number 375
Parameter Type Read Only, Source
Display Units / Drive Units Bits
Factory Default 0
Minimum Value 0
Maximum Value 0FE Hex
File – Group Communications I/O – SCANport Owners
Enums Bit 1 = Port 1 Bit 2 = Port 2 Bit 3 = Port 3 Bit 4 = Port 4
Bit 5 = Port 5 Bit 6 = Channel A Bit 7 = Channel B
Page view 165