Rockwell-automation 1336T ControlNet Frn1.02 Rev 1.5 User Manual Page 177

  • Download
  • Add to my manuals
  • Print
  • Page
    / 217
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 176
6–35Parameters
Publication 1336 FORCE–5.18 ––March, 1999
440
SCANport Fault Selection
[SP Fault Sel]
SP Fault Sel indicates which ports will cause a drive
soft fault on loss of communications.
Parameter Number 440
Parameter Type Read/Write, Sink
Display Units / Drive Units Bits
Factory Default 0011 1110
Minimum Value 0000 0000
Maximum Value 0011 1110
File – Group Diagnostics – Fault Select/Status
Communications I/O – Fault Select/Status
Enums
Bit 7 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Enums Fault
Port 1 SP Pt1 Timeout (Flt 26038)
Port 2 SP Pt2 Timeout (Flt 26039)
Port 3 SP Pt3 Timeout (Flt 26040)
Port 4 SP Pt4 Timeout (Flt 26041)
Port 5 SP Pt5 Timeout (Flt 26042)
SP Offline
441
SCANport Warning Selection
[SP Warn Sel]
SP Warn Sel indicates which ports will cause a drive
warning on loss of communications.
Parameter Number 441
Parameter Type Read/Write Sink
Display Units / Drive Units Bits
Factory Default 0011 1110
Minimum Value 0000 0000
Maximum Value 0011 1110
File – Group Diagnostics – Fault Select/Status
Communications I/O – Fault Select/Status
Enums
Bit 7 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Enums Warning
Port 1 SP Pt1 Timeout (Flt 26038)
Port 2 SP Pt2 Timeout (Flt 26039)
Port 3 SP Pt3 Timeout (Flt 26040)
Port 4 SP Pt4 Timeout (Flt 26041)
Port 5 SP Pt5 Timeout (Flt 26042)
SP Offline
442
SCANport Fault Status
[SP Fault Sts]
SP Fault Sts indicates which communications soft
faults the drive has encountered at the ports.
Parameter Number 442
Parameter Type Read Only, Source
Display Units / Drive Units Bits
Factory Default 0011 1110
Minimum Value 0000 0000
Maximum Value 0011 1110
File – Group Diagnostics – Fault Select/Status
Communications I/O – Fault Select/Status
Enums
Bit 7 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Enums Fault
Port 1 SP Pt1 Timeout (Flt 26038)
Port 2 SP Pt2 Timeout (Flt 26039)
Port 3 SP Pt3 Timeout (Flt 26040)
Port 4 SP Pt4 Timeout (Flt 26041)
Port 5 SP Pt5 Timeout (Flt 26042)
SP Offline
Page view 176
1 2 ... 172 173 174 175 176 177 178 179 180 181 182 ... 216 217

Comments to this Manuals