Rockwell-automation 2099-BMxx Kinetix 7000 High Power Servo Drive User User Manual Page 150

  • Download
  • Add to my manuals
  • Print
  • Page
    / 190
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 149
150 Rockwell Automation Publication 2099-UM001D-EN-P - December 2012
Appendix A Specifications and Dimensions
Power Specifications
This section contains power specifications for the Kinetix 7000 drive.
Attribute
2099-BM06-S 2099-BM07-S 2099-BM08-S 2099-BM09-S 2099-BM10-S 2099-BM11-S 2099-BM12-S
AC input voltage 342…528V AC rms three-phase (380…480V nom)
AC input frequency 47…63 Hz
Bandwidth
(1)
Velocity loop
Current loop
500 Hz
1300 Hz
500 Hz
500 Hz
PWM frequency 4 kHz 2 kHz
Main AC input current
Nom (rms)
Max inrush (A peak)
36.7 A
18.0 A
47.7 A
18.0 A
59.6 A
18.0 A
90.1 A
96.0 A
117 A
118 A
169 A
141 A
233 A
141 A
DC input voltage 450…750V DC
DC input current 42.9 A 55.7 A 69.7 A 105 A 137 A 204 A 281 A
Control power input Voltage 18…30V DC (24V DC, nom)
Control power DC input current
Nom (rms)
Maximum inrush (rms)
3.3 A
6.0 A
Continuous output current (rms) 40.0 A 52.0 A 65.0 A 96.0 A 125 A 180 A 248 A
Continuous output current (0-pk) 56.0 A 73.0 A 92.0 A 135 A 176 A 254 A 351 A
Peak output current (rms)
3 s duration
60 s duration
68.0 A
51.0 A
80.0 A
60.0 A
104 A
78.0A
154 A
115 A
163 A
138 A
312 A
234 A
372 A
273 A
Peak output current (0-pk)
3 s duration
60 s duration
96.0 A
72.0 A
113 A
84.8 A
147 A
110 A
217.7 A
162.6 A
230.5 A
195 A
441 A
331 A
526 A
386 A
Bus overvoltage 800V DC
Bus undervoltage 275…560V DC
(2)
Continuous power output, nom 22 kW 30 kW 37 kW 56 kW 75 kW 112 kW 149 kW
Continuous power output (Hp) 30 Hp 40 Hp 50 Hp 75 Hp 100 Hp 150 Hp 200 Hp
Maximum power cycles/minute
AC line
DC bus
4 per minute (pre-charge provided by drive)
2 per minute (DC pre-charge provided by the regenerative power supply)
DC bus discharge time 3 minutes after removal of main AC power
Efficiency 97.5%
Total capacitance
(3)
1800 μF 2400 μF 3000 μF 4500 μF 6000 μF 8400 μF 8400 μF
Short circuit current rating 200,000 A (rms) symmetrical
(1) Bandwidth values vary based on tuning parameters and mechanical components.
(2) Bus undervoltage will vary based on input line voltage.
(3) If DC input is supplied to 2099-BM09-S, 2099-BM10-S, 2099-BM11-S, or 2099-BM12-S drives, the precharge capability must be provided at the system level. Disconnect switches must not be used
between the input of the drive and a common DC bus without the use of an external precharge device.
Page view 149
1 2 ... 145 146 147 148 149 150 151 152 153 154 155 ... 189 190

Comments to this Manuals

No comments